The multiple-channel cochlear implant: the interface between sound and the central nervous system for hearing, speech, and language in deaf people—a personal perspective
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The multiple-channel cochlear implant is the first sensori-neural prosthesis to effectively and safely bring electronic technology into a direct physiological relation with the central nervous system and human consciousness, and to give speech perception to severely-profoundly deaf people and spoken language to children. Research showed that the place and temporal coding of sound frequencies could be partly replicated by multiple-channel stimulation of the auditory nerve. This required safety studies on how to prevent the effects to the cochlea of trauma, electrical stimuli, biomaterials and middle ear infection. The mechanical properties of an array and mode of stimulation for the place coding of speech frequencies were determined. A fully implantable receiver–stimulator was developed, as well as the procedures for the clinical assessment of deaf people, and the surgical placement of the device. The perception of electrically coded sounds was determined, and a speech processing strategy discovered that enabled late-deafened adults to comprehend running speech. The brain processing systems for patterns of electrical stimuli reproducing speech were elucidated. The research was developed industrially, and improvements in speech processing made through presenting additional speech frequencies by place coding. Finally, the importance of the multiple-channel cochlear implant for early deafened children was established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tykocinski, M., Shepherd, R. K., & Clark, G. M. (1995) · Hearing Research · doi:10.1016/0378-5955(95)00108-g · Cited by 61
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Clark, G. M. (2015) · Hearing Research · doi:10.1016/j.heares.2014.08.002 · Cited by 161
“All frequencies were coded on a place basis (Modified; Clark 2006).”
BackgroundMethodInfluentialSelf-citationRetinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
“After the development and successful clinical application of cochlear implants (Rauschecker and Shannon, 2002; Clark, 2006), neural prostheses were exploited in the treatment of diverse acquired or hereditary neural defects including visual impairments.”
Microstimulation of visual cortex to restore vision
Tehovnik, E. J., Slocum, W. M., Smirnakis, S. M., & Tolias, A. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17524-6 · Cited by 71
“It is noteworthy that some 10 years of development using behaving animals as test subjects preceded the implantation and testing of a cochlear device in humans that decades later has been used successfully to restore function to the hearing impaired (Clark, 2003, 2006; Clark et al., 1972).”
Background
Metadata
- Authors
- Clark, G. M.
- Venue
- Philosophical Transactions of the Royal Society B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 2006-02-13
- Volume
- 361
- Issue
- 1469
- Pages
- 791-810
- ISSN
- 0962-8436 (ISSN-L)
- 1471-2970
- OpenAlex
- W2108340697
- Cited by
- 111
- References
- 1
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.