The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Precision 1070 nm Ultrafast Laser-induced Photothrombosis (PLP) of Depth-targeted Vessels in vivo
Open accessPreprint — published as 10.1002/smtd.202200917 · Paper page
Abstract
The cerebrovasculature plays an essential role in neurovascular and homeostatic functions in health and disease conditions. Many efforts have been made for developing vascular thrombosis methods to study vascular dysfunction in vivo , while technical challenges remain, such as accuracy and depth-selectivity to target single vessel in the cerebral cortex. Herein, we first demonstrates the evaluation and quantification of the feasibility and effects of Rose Bengal (RB)-induced photothrombosis with 720-1070 nm ultrafast lasers in raster scan. A flexible and reproducible approach is then proposed to employ a 1070 nm ultrafast laser with spiral scan for producing RB-induced occlusion, which is described as precision ultrafast laser-induced photothrombosis (PLP). Combine with two-photon microscopy imaging, this PLP displays highly precise and fast occlusion induction of various vessel types, sizes, and depths, which enhances the precision and power of the photothrombosis protocol. Overall, the PLP method provides a real-time, practical, precise, and depth-selected single-vessel photothrombosis technology in cerebral cortex with commercially available optical equipment, which is crucial for exploring brain vascular function with high spatial temporal resolution in brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, S., & Murphy, T. H. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050119 · Cited by 193
Research works printed but not linked: 47
- 2017, The Neurovascular Unit Coming of Age: A Journey through Neurovascular Coupling in Health and Disease, Neuron, 96, 17, 10.1016/j.neuron.2017.07.030 · DOI · Paper page
- 10.1016/j.neuron.2013.10.008 · DOI · Paper page
- 10.1152/japplphysiol.00966.2005 · DOI
- 10.1038/nn.3426 · DOI · Paper page
- 2020, Mapping the Fine-Scale Organization and Plasticity of the Brain Vasculature, Cell, 180, 780, 10.1016/j.cell.2020.01.028 · DOI
- 2021, Brain microvasculature has a common topology with local differences in geometry that match metabolic load, Neuron, 109, 1168, 10.1016/j.neuron.2021.02.006 · DOI
- Chen, B. R ., Bouchard, M. B ., McCaslin, A. F ., Burgess, S. A . & Hillman, E. M . High-speed vascular dynamics of the hemodynamic response. Neuroimage 54 (2011). · DOI
- 10.1038/sj.bmt.1701832 · DOI
- 10.1146/annurev-neuro-071013-014111 · DOI
- 2018, Linking brain vascular physiology to hemodynamic response in ultra-high field MRI, Neuroimage, 168, 279, 10.1016/j.neuroimage.2017.02.063 · DOI
- 10.1038/324361a0 · DOI
- 2017, Intrinsic signal optical imaging of visual brain activity: Tracking of fast cortical dynamics, Neuroimage, 148, 160, 10.1016/j.neuroimage.2017.01.006 · DOI
- 10.1038/s41593-018-0234-x · DOI · Paper page
- 10.1038/s41593-018-0329-4 · DOI · Paper page
- 10.1038/s41582-019-0281-2 · DOI · Paper page
- 10.1016/j.neuron.2008.01.003 · DOI · Paper page
- 10.1038/35084005 · DOI · Paper page
- 10.1038/nature07664 · DOI · Paper page
- 2007, Acute ischemic stroke: Overview of major experimental rodent models, pathophysiology, and therapy of focal cerebral ischemia, Pharmacol Biochem Be, 87, 179, 10.1016/j.pbb.2007.04.015 · DOI
- 10.1161/01.STR.20.1.84 · DOI · Paper page
- 10.1038/sj.jcbfm.9600591 · DOI
- 10.1016/j.neuron.2014.08.052 · DOI
- 2017, Control of cerebral ischemia with magnetic nanoparticles, Nat Methods, 14, 160, 10.1038/nmeth.4105 · DOI
- 10.1007/s004150050021 · DOI
- 10.1038/nmeth844 · DOI · Paper page
- 10.1126/sciadv.aan9388 · DOI
- 10.1523/JNEUROSCI.1085-05.2005 · DOI · Paper page
- 10.1002/ana.410170513 · DOI · Paper page
- 10.1161/hs0202.102730 · DOI
- 10.1016/j.celrep.2018.06.119 · DOI
- 2022, Depth-targeted intracortical microstroke by two-photon photothrombosis in rodent brain, Neurophotonics, 9, 021910
- 10.1016/j.cmet.2015.10.010 · DOI · Paper page
- Roche, M . et al. In vivo imaging with a water immersion objective affects brain temperature, blood flow and oxygenation. Elife 8 (2019). · DOI
- 10.3389/fphys.2017.00979 · DOI
- Wu, X . et al. Tether-free photothermal deep-brain stimulation in freely behaving mice via wide-field illumination in the near-infrared-II window. Nat Biomed Eng (2022). · DOI · Paper page
- Horton, N. G . et al. In vivo three-photon microscopy of subcortical structures within an intact mouse brain. Nat Photonics 7 (2013). · DOI · Paper page
- 10.1088/0022-3727/38/15/004 · DOI · Paper page
- 10.1371/journal.pone.0104250 · DOI
- Linz, N ., Freidank, S ., Liang, X.-X . & Vogel, A . Wavelength dependence of femtosecond laser-induced breakdown in water and implications for laser surgery. Physical Review B 94 (2016). · DOI
- 10.1016/S0006-3495(01)76173-5 · DOI · Paper page
- 2005, Mechanisms of femtosecond laser nanosurgery of cells and tissues, Applied Physics B, 81, 1015, 10.1007/s00340-005-2036-6 · DOI
- 10.1016/S1474-4422(10)70104-6 · DOI · Paper page
- 10.1016/S1474-4422(13)70060-7 · DOI · Paper page
- Zhu, L . et al. Imaging microvasculature network evolution and neurodegeneration with precise photothrombosis approach. bioRxiv, 2021.2011.2029.470313 (2021). · DOI
- 10.1038/nprot.2014.165 · DOI
- 10.1371/journal.pone.0038590 · DOI
- 2021, VasoMetrics: unbiased spatiotemporal analysis of microvascular diameter in multi-photon imaging applications, Quant Imaging Med Surg, 11, 969
Metadata
- Authors
- Zhu, L., Wang, M., Fu, P., Liu, Y., Zhang, H., Roe, A. W., & Xi, W.
- Affiliations
- Second Affiliated Hospital of Zhejiang University (CN)
- Venue
- Small Methods
- Publisher
- openRxiv
- Published
- 2022-06-26
- Volume
- 7
- Issue
- 1
- Pages
- e2200917-e2200917
- ISSN
- 2366-9608 (ISSN-L)
- OpenAlex
- W4307340620
- Cited by
- 8
- References
- 1
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 1
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Small Methods (publishedVersion, cc-by-nc-nd)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (U20A2022‐1, 91632105, 81961128029, 2018YFA0701400)
- National Key Research and Development Program of China (2018YFA0701400)
- Fundamental Research Funds for the Central Universities (226–2022-00083, 2019XZZX003–20, 2019XZZX003)
- Key Research and Development Program of Zhejiang Province (2020C03004)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nonlinear Optical Materials Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Laser Material Processing Techniques
- Keywords
- photothrombosis, rose bengal, cerebral cortex, spiral scan, two-photon microscopy, vascular dysfunction, cerebrovascular function
- MeSH terms
- Brain, Humans, Lasers, Rose Bengal, Thrombosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review