A portable and cost-effective microfluidic system for massively parallel single-cell transcriptome profiling
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Single-cell technologies are becoming increasingly widespread and have been revolutionizing our understanding of cell identity, state, diversity and function. However, current platforms can be slow to apply to large-scale studies and resource-limited clinical arenas due to a variety of reasons including cost, infrastructure, sample quality and requirements. Here we report DNBelab C4 (C4), a negative pressure orchestrated, portable and cost-effective device that enables high-throughput single-cell transcriptional profiling. C4 system can efficiently allow discrimination of species-specific cells at high resolution and dissect tissue heterogeneity in different organs, such as murine lung and cerebral cortex. Finally, we show that the C4 system is comparable to existing platforms but has huge benefits in cost and portability and, as such, it will be of great interest for the wider scientific community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Droplet barcoding for single-cell transcriptomics applied to embryonic stem cells
Klein, A. M., Mazutis, L., Akartuna, I., Tallapragada, N., Veres, A., Li, V., Peshkin, L., Weitz, D. A., & Kirschner, M. W. (2015) · Cell · doi:10.1016/j.cell.2015.04.044 · Cited by 3,356
Current best practices in single-cell RNA-seq analysis: a tutorial
Luecken, M. D., & Theis, F. J. (2019) · Molecular Systems Biology · doi:10.15252/msb.20188746 · Cited by 2,231 · cited 1×
“These methods, in comparison to low-throughput plate19 based methods, are robust in cell type classification since profiling higher number of 20 cells can reduce the negative impact from technical and intrinsic noise [6].”
MethodMassively parallel single-nucleus RNA-seq with DroNc-seq
Habib, N., Avraham-Davidi, I., Basu, A., Burks, T., Shekhar, K., Hofree, M., Choudhury, S. R., Aguet, F., Gelfand, E., Ardlie, K., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4407 · Cited by 1,069
Systematic comparison of single-cell and single-nucleus RNA-sequencing methods
Ding, J., Adiconis, X., Simmons, S. K., Kowalczyk, M. S., Hession, C. C., Marjanovic, N. D., Hughes, T. K., Wadsworth, M. H., Burks, T., Nguyen, L. T., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0465-8 · Cited by 871
Single-nucleus and single-cell transcriptomes compared in matched cortical cell types
Bakken, T. E., Hodge, R. D., Miller, J. A., Yao, Z., Nguyen, T. N., Aevermann, B., Barkan, E., Bertagnolli, D., Casper, T., Dee, N., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0209648 · Cited by 608
Benchmarking single-cell RNA-sequencing protocols for cell atlas projects
Mereu, E., Lafzi, A., Moutinho, C., Ziegenhain, C., McCarthy, D. J., Álvarez-Varela, A., Batlle, E., Sagar, Grün, D., Lau, J. K., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0469-4 · Cited by 499
From tissues to cell types and back: single-cell gene expression analysis of tissue architecture
Chen, X., Teichmann, S. A., & Meyer, K. B. (2018) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-080917-013452 · Cited by 112
Cited by
Single‐cell RNA sequencing technologies and applications: A brief overview
Jovic, D., Liang, X., Zeng, H., Lin, L., Xu, F., & Luo, Y. (2022) · Clinical and Translational Medicine · doi:10.1002/ctm2.694 · Cited by 1,271
Zhu, L., Yang, P., Zhao, Y., Zhuang, Z., Wang, Z., Song, R., Zhang, J., Liu, C., Gao, Q., Xu, Q., et al. (2020) · Immunity · doi:10.1016/j.immuni.2020.07.009 · Cited by 385
Self-citationSingle-cell spatial transcriptome reveals cell-type organization in the macaque cortex
Chen, A., Sun, Y., Lei, Y., Li, C., Liao, S., Meng, J., Bai, Y., Liu, Z., Liang, Z., Zhu, Z., et al. (2023) · Cell · doi:10.1016/j.cell.2023.06.009 · Cited by 232
Self-citationSui, Q., Zhang, X., Chen, C., Tang, J., Yu, J., Li, W., Han, K., Jiang, W., Liao, L., Kong, L., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-35096-6 · Cited by 165
Xi, C., Yan, Z., Bai, D., Zhang, Y., Wang, B., Han, X., Wu, L., Shi, X., Hu, Z., Tang, M., et al. (2024) · Protein & Cell · doi:10.1093/procel/pwae006 · Cited by 18
“DNBelab C Series Single-Cell Library Prep Set (MGI) was utilized as previously described (Liu et al., 2019) for single-cell RNA-seq library preparation.”
MethodSelf-citationPlant-on-chip: Core morphogenesis processes in the tiny plant Wolffia australiana
Li, F., Yang, J.-J., Sun, Z.-Y., Wang, L., Qi, L.-Y., A, S., Liu, Y.-Q., Zhang, H.-M., Dang, L.-F., Wang, S.-J., et al. (2023) · PNAS Nexus · doi:10.1093/pnasnexus/pgad141 · Cited by 15
Self-citation
Metadata
- Authors
- Liu, C., Wu, T., Fan, F., Liu, Y., Wu, L., Junkin, M., Wang, Z., Yu, Y., Wang, W., Wei, W., Yuan, Y., Wang, M., Cheng, M., Wei, X., Xu, J., Shi, Q., Liu, S., Chen, A., Wang, O., Ni, M., Zhang, W., Shang, Z., Lai, Y., Guo, P., Ward, C., Volpe, G., Wang, L., Zheng, H., Liu, Y., Peters, B. A., Beecher, J., Zhang, Y., Esteban, M. A., Hou, Y., Xu, X., Chen, I.-J., & Liu, L.
- Venue
- bioRxiv (Cold Spring Harbor Laboratory)
- Publisher
- openRxiv
- Published
- 2019-10-25
- OpenAlex
- W2981970954
- Cited by
- 86
- References
- 7
- Type
- posted content
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.