Texture analysis of non-small cell lung cancer on unenhanced computed tomography: initial evidence for a relationship with tumour glucose metabolism and stage
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The aim was to undertake an initial study of the relationship between texture features in computed tomography (CT) images of non-small cell lung cancer (NSCLC) and tumour glucose metabolism and stage. This retrospective pilot study comprised 17 patients with 18 pathologically confirmed NSCLC. Non-contrast-enhanced CT images of the primary pulmonary lesions underwent texture analysis in 2 stages as follows: (a) image filtration using Laplacian of Gaussian filter to differentially highlight fine to coarse textures, followed by (b) texture quantification using mean grey intensity (MGI), entropy (E) and uniformity (U) parameters. Texture parameters were compared with tumour fluorodeoxyglucose (FDG) uptake (standardised uptake value (SUV)) and stage as determined by the clinical report of the CT and FDG-positron emission tomography imaging. Tumour SUVs ranged between 2.8 and 10.4. The number of NSCLC with tumour stages I, II, III and IV were 4, 4, 4 and 6, respectively. Coarse texture features correlated with tumour SUV (E: r = 0.51, p = 0.03; U: r = -0.52, p = 0.03), whereas fine texture features correlated with tumour stage (MGI: rs = 0.71, p = 0.001; E: rs = 0.55, p = 0.02; U: rs = -0.49, p = 0.04). Fine texture predicted tumour stage with a kappa of 0.7, demonstrating 100% sensitivity and 87.5% specificity for detecting tumours above stage II ( p = 0.0001). This study provides initial evidence for a relationship between texture features in NSCLC on non-contrast-enhanced CT and tumour metabolism and stage. Texture analysis warrants further investigation as a potential method for obtaining prognostic information for patients with NSCLC undergoing CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-11-200311180-00013 · Cited by 687
Travis, W. D., Travis, L. B., & Devesa, S. S. (1995) · Cancer · doi:10.1002/1097-0142(19950101)75:1+<191::aid-cncr2820751307>3.0.co;2-y · Cited by 582
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Berghmans, T., Dusart, M., Paesmans, M., Hossein-Foucher, C., Buvat, I., Castaigne, C., Scherpereel, A., Mascaux, C., Moreau, M., Roelandts, M., et al. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31815e6d6b · Cited by 524
Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 280
Miles, K. A., Ganeshan, B., Griffiths, M. R., Young, R. C. D., & Chatwin, C. R. (2009) · Radiology · doi:10.1148/radiol.2502071879 · Cited by 253
Self-citationAutomated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
Zhao, S., Kuge, Y., Mochizuki, T., Takahashi, T., Nakada, K., Sato, M., Takei, T., & Tamaki, N. (2005) · PubMed · Cited by 194
McNitt‐Gray, M. F., Hart, E. M., Wyckoff, N., Sayre, J. W., Goldin, J. G., & Aberle, D. R. (1999) · Medical Physics · doi:10.1118/1.598603 · Cited by 184
Patient-specific models for lung nodule detection and surveillance in CT images
Brown, M. S., McNitt-Gray, M. F., Goldin, J. G., Suh, R. D., Sayre, J. W., & Aberle, D. R. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974919 · Cited by 169
Ganeshan, B., Miles, K. A., Young, R. C. D., & Chatwin, C. R. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.12.005 · Cited by 160
Self-citationKido, S., Kuriyama, K., Higashiyama, M., Kasugai, T., & Kuroda, C. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200207000-00017 · Cited by 90
Matteis, S. D., Consonni, D., & Bertazzi, P. A. (2008) · PubMed · Cited by 74
In Search of Biologic Correlates for Liver Texture on Portal-Phase CT
Ganeshan, B., Miles, K. A., Young, R. C. D., & Chatwin, C. R. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.05.023 · Cited by 70
Self-citationAutomated detection of lung nodules in CT scans: Effect of image reconstruction algorithm
Armato, S. G., Altman, M. B., & Rivière, P. J. L. (2003) · Medical Physics · doi:10.1118/1.1544679 · Cited by 53
Na, I. I., Byun, B. H., Kang, H. J., Cheon, G. J., Koh, J. S., Kim, C. H., Choe, D. H., Ryoo, B., Lee, J. C., Lim, S. M., et al. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-4074 · Cited by 43
Three-Dimensional Selective-Scale Texture Analysis of Computed Tomography Pulmonary Angiograms
Ganeshan, B., Miles, K. A., Young, R. C. D., & Chatwin, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181690091 · Cited by 36
Self-citationGaliè, M., Farace, P., Nanni, C., Spinelli, A. E., Nicolato, E., Boschi, F., Magnani, P., Trespidi, S., Ambrosini, V., Fanti, S., et al. (2007) · Neoplasia · doi:10.1593/neo.07541 · Cited by 28
Cited by
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Machine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878
Self-citationCT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Metadata
- Authors
- Ganeshan, B., Abaleke, S., Young, R. C. D., Chatwin, C. R., & Miles, K. A.
- Venue
- Cancer Imaging
- Publisher
- E-MED LTD
- Published
- 2010
- Volume
- 10
- Issue
- 1
- Pages
- 137-143
- ISSN
- 1470-7330 (ISSN-L)
- OpenAlex
- W1964620951
- Cited by
- 324
- References
- 19
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.