The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Computational ghost imaging
Open accessAbstract
Ghost-imaging experiments correlate the outputs from two photodetectors: a high spatial-resolution (scanning pinhole or charge-coupled-device camera) detector that measures a field which has not interacted with the object to be imaged and a bucket (single-pixel) detector that collects a field that has interacted with the object. We describe a computational ghost-imaging arrangement that uses only a single-pixel detector. This configuration affords background-free imagery in the narrow-band limit and a three-dimensional sectioning capability. It clearly indicates the classical nature of ghost-image formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Probability, Random Variables, and Stochastic Processes
Papoulis, A., & Hoffman, J. G. (1967) · Physics Today · doi:10.1063/1.3034123 · Cited by 4,107
Optical imaging by means of two-photon quantum entanglement
Pittman, T. B., Shih, Y. H., Strekalov, D. V., & Sergienko, A. V. (1995) · Physical Review A · doi:10.1103/physreva.52.r3429 · Cited by 2,142
Ghost Imaging with Thermal Light: Comparing Entanglement and ClassicalCorrelation
Gatti, A., Brambilla, E., Bache, M., & Lugiato, L. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.093602 · Cited by 930
Two-Photon Imaging with Thermal Light
Valencia, A., Scarcelli, G., D’Angelo, M., & Shih, Y. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.063601 · Cited by 838
Correlated imaging, quantum and classical
Gatti, A., Brambilla, E., Bache, M., & Lugiato, L. A. (2004) · Physical Review A · doi:10.1103/physreva.70.013802 · Cited by 417
Can Two-Photon Correlation of Chaotic Light Be Considered as Correlation of Intensity Fluctuations?
Scarcelli, G., Berardi, V., & Shih, Y. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.063602 · Cited by 309
Ghost-imaging experiment by measuring reflected photons
Meyers, R., Deacon, K. S., & Shih, Y. (2008) · Physical Review A · doi:10.1103/physreva.77.041801 · Cited by 238
Ghost interference with partially coherent radiation
Cai, Y., & Zhu, S.-Y. (2004) · Optics Letters · doi:10.1364/ol.29.002716 · Cited by 195
Unified theory of ghost imaging with Gaussian-state light
Erkmen, B. I., & Shapiro, J. H. (2008) · Physical Review A · doi:10.1103/physreva.77.043809 · Cited by 182
Self-citationResolution of quantum and classical ghost imaging
D’Angelo, M., Valencia, A., Rubin, M. H., & Shih, Y. H. (2005) · Physical Review A · doi:10.1103/physreva.72.013810 · Cited by 103
Cited by
Katz, O., Bromberg, Y., & Silberberg, Y. (2009) · Applied Physics Letters · doi:10.1063/1.3238296 · Cited by 1,018
Experimental X-Ray Ghost Imaging
Pelliccia, D., Rack, A., Scheel, M., Cantelli, V., & Paganin, D. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.113902 · Cited by 367
Simultaneous real-time visible and infrared video with single-pixel detectors
Edgar, M. P., Gibson, G. M., Bowman, R. W., Sun, B., Radwell, N., Mitchell, K. J., Welsh, S. S., & Padgett, M. J. (2015) · Scientific Reports · doi:10.1038/srep10669 · Cited by 332
An introduction to ghost imaging: quantum and classical
Padgett, M. J., & Boyd, R. W. (2017) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2016.0233 · Cited by 282
Metadata
- Authors
- Shapiro, J. H.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2008-12-18
- Volume
- 78
- Issue
- 6
- Pages
- IThK7-IThK7
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1560002780
- Cited by
- 1,531
- References
- 11
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.