Hertz-level measurement of the40Ca+4s2S1/2–3d2D5/2clock transition frequency with respect to the SI second through the Global Positioning System

Open access
Huang, Y., Cao, J., Liu, P., Liang, K., Ou, B., Guan, H., Huang, X., Li, T., Gao, K. · 2012 · Physical Review A
Cited by 61

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We have measured the absolute frequency of a clock transition at the 10${}^{\ensuremath{-}15}$ level with a single, trapped, laser-cooled ${}^{40}$Ca${}^{+}$ ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time $>$2 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{6}$ s, the absolute frequency of the ${}^{40}$Ca${}^{+}$ 4$s$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}$--3$d$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}$ clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{\ensuremath{-}15}$.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.85.030503

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Huang, Y., Cao, J., Liu, P., Liang, K., Ou, B., Guan, H., Huang, X., Li, T., & Gao, K.
Venue
Physical Review A
Published
2012-03-23
Volume
85
Issue
3
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W1577254313
Cited by
61
References
3
FWCI
3.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.