Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
We used precise point positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled [Formula: see text] ions operated at the National Physical Laboratory (NPL), U.K. and the Physikalisch-Technische Bundesanstalt (PTB), Germany. At both institutes, an active hydrogen maser serves as a flywheel oscillator which is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the (2)S1/2(F=0)-(2)D3/2(F=2) electric quadrupole transition in [Formula: see text] via an optical femtosecond frequency comb. To profit from long coherent GPS-link measurements, we extrapolate the fractional frequency difference over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS-link instability. We determined the total statistical uncertainty consisting of the GPS-link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference [Formula: see text] of -1.3×10(-15) with a combined uncertainty of 1.2×10(-15) for a total measurement time of 67 h. This result is consistent with an agreement of the frequencies realized by both optical clocks and with recent absolute freque…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These techniques achieve a typical uncertainty at the level of 10 -15 at 1 d of averaging time that limits the comparison of optical clocks.”
From Intercontinental comparison of optical atomic clocks through very long baseline interferometry (2021) · cites this paper as [23]
Citations
Cites
The International GNSS Service in a changing landscape of Global Navigation Satellite Systems
Dow, J. M., Neilan, R. E., & Rizos, C. (2009) · Journal of Geodesy · doi:10.1007/s00190-008-0300-3 · Cited by 1,522 · cited 1×
“The comparison of the masers via GPS was done using PPP with the NRCan PPP software [13] and final IGS orbit and 30-s clock products [14].”
MethodPrecise Point Positioning Using IGS Orbit and Clock Products
Kouba, J., & Héroux, P. (2001) · GPS Solutions · doi:10.1007/pl00012883 · Cited by 1,488 · cited 1×
“The comparison of the masers via GPS was done using PPP with the NRCan PPP software [13] and final IGS orbit and 30-s clock products [14].”
MethodGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468 · cited 1×
“Details on the experimental setups can be found in [7]–[9].”
BackgroundSelf-citation8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286 · cited 1×
“At PTB, the E2 probe laser system was measured versus the probe laser system of the strontium lattice clock at PTB [12] which shows a relative instability of ≤ 10−16 between 1 and 1000 s.”
MethodSelf-citationExternal-field shifts of the 199-Hg(+) optical frequency standard
Itano, W. M. (2000) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.105.065 · Cited by 221 · cited 1×
“Due to this relation, the shift effect is cancelled by averaging the observed transition frequency for three mutually orthogonal orientations of the quantization axis [11].”
BackgroundGeodetic techniques for time and frequency comparisons using GPS phase and code measurements
Ray, J., & Senior, K. (2005) · Metrologia · doi:10.1088/0026-1394/42/4/005 · Cited by 173 · cited 1×
“GPS precise point positioning (PPP) links between distant clocks reach an instability of 10−15 at 1 day averaging time [1], [2].”
Background1 × 10−16frequency transfer by GPS PPP with integer ambiguity resolution
Petit, G., Kanj, A., Loyer, S., Delporte, J., Mercier, F., & Perosanz, F. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/301 · Cited by 168 · cited 1×
“niques like integer PPP [16] or revised RINEX-shift [17] and more sophisticated weighting schemes for the frequency averages [18] will allow further improved frequency comparisons”
BackgroundMadej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155
Generalized Ramsey Excitation Scheme with Suppressed Light Shift
Huntemann, N., Lipphardt, B., Okhapkin, M. V., Tamm, C., Peik, E., Тайченачев, А. В., & Yudin, V. I. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.213002 · Cited by 133 · cited 1×
“At PTB, in contrast to the previously published work [7], [8], the nonlinear frequency drift of the E2 probe laser system has been reduced by about one order of magnitude by prestabilizing its frequency to a more stable reference cavity [10].”
Self-citationTamm, C., Weyers, S., Lipphardt, B., & Peik, E. (2009) · Physical Review A · doi:10.1103/physreva.80.043403 · Cited by 103 · cited 1×
“At PTB, in contrast to the previously published work [7], [8], the nonlinear frequency drift of the E2 probe laser system has been reduced by about one order of magnitude by prestabilizing its frequency to a more stable reference cavity [10].”
Self-citation
Cited by
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Self-citationRealizing quantum gates with optically addressable Yb + 171 ion qudits
Aksenov, M. A., Zalivako, I. V., Semerikov, I. A., Borisenko, A. S., Semenin, N. V., Sidorov, P., Fedorov, A. K., Khabarova, K. Y., & Kolachevsky, N. (2023) · Physical Review A · doi:10.1103/physreva.107.052612 · Cited by 51
Metadata
- Authors
- Leute, J., Huntemann, N., Lipphardt, B., Tamm, C., Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., Wallin, A., Merimaa, M., Gill, P., & Peik, E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- National Physical Laboratory (GB)
- National metrology institute VTT MIKES (FI)
- ORCID
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Published
- 2016-07
- Volume
- 63
- Issue
- 7
- Pages
- 981-985
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2964181237
- Cited by
- 29
- References
- 18
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 4 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 4 · 2017: 3 · 2016: 1
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (publishedVersion)
- PubMed (publishedVersion)
- Funders
- EMRP (SIB04)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- 171Yb, precise point positioning, femtosecond optical frequency comb, E2 transitions, extrapolation uncertainty, absolute frequency measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP. https://app.cochat.ai/papers/10.1109/tuffc.2016.2524988
- The paper
- Leute, J., Huntemann, N., Lipphardt, B., Tamm, C., Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., Wallin, A., Merimaa, M., Gill, P., & Peik, E. (2016). Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2016.2524988
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.