Simultaneous dual-species matter-wave accelerometer
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We report the realization of a matter-wave interferometer based on Raman transitions which simultaneously interrogates two different atomic species (${}^{87}$Rb and ${}^{85}$Rb). The simultaneous aspect of our experiment presents encouraging preliminary results for future dual-species atom interferometry projects and seems very promising by taking advantage of a differential acceleration measurement. Indeed, the resolution of our differential accelerometer remains lower than $3.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ even with vibration levels up to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\phantom{\rule{0.16em}{0ex}}\text{g}$ thanks to common-mode vibration noise rejection. An atom-based test of the weak equivalence principle has also been carried out leading to a differential free fall measurement between both isotopes of $\ensuremath{\Delta}g/g=(1.2\ifmmode\pm\else\textpm\fi{}3.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Precision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
Sensitive absolute-gravity gradiometry using atom interferometry
McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J., & Kasevich, M. A. (2002) · Physical Review A · doi:10.1103/physreva.65.033608 · Cited by 586
New Determination of the Fine Structure Constant and Test of the Quantum Electrodynamics
Bouchendira, R., Cladé, P., Guellati-Khélifa, S., Nez, F., & Biraben, F. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.080801 · Cited by 568
Atom Interferometer Measurement of the Newtonian Constant of Gravity
Fixler, J. B., Foster, G. T., McGuirk, J. M., & Kasevich, M. A. (2007) · Science · doi:10.1126/science.1135459 · Cited by 554
Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer
Kasevich, M., & Chu, S. (1992) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00325375 · Cited by 550
Atomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Interferometry with Bose-Einstein Condensates in Microgravity
Müntinga, H., Ahlers, H., Krutzik, M., Wenzlawski, A., Arnold, S., Becker, D., Bongs, K., Dittus, H., Duncker, H., Gaaloul, N., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.093602 · Cited by 415
Detecting inertial effects with airborne matter-wave interferometry
Geiger, R., Ménoret, V., Stern, G., Zahzam, N., Cheinet, P., Battelier, B., Villing, A., Moron, F., Lours, M., Bidel, Y., et al. (2011) · Nature Communications · doi:10.1038/ncomms1479 · Cited by 398
Self-citationBerman, P. R. (1996) · Cited by 394
Testing General Relativity with Atom Interferometry
Dimopoulos, S., Graham, P. W., Hogan, J. M., & Kasevich, M. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.111102 · Cited by 362
Atomic gravitational wave interferometric sensor
Dimopoulos, S., Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2008) · Physical Review D · doi:10.1103/physrevd.78.122002 · Cited by 335
Atom-Interferometry Tests of the Isotropy of Post-Newtonian Gravity
Müller, H., Chiow, S.-W., Herrmann, S., Chu, S., & Chung, K.-Y. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.031101 · Cited by 333
Atomic velocity selection using stimulated Raman transitions
Kasevich, M., Weiss, D. S., Riis, E., Moler, K., Kasapi, S., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2297 · Cited by 305
Fray, S., Diez, C. A., Hänsch, T. W., & Weitz, M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.240404 · Cited by 303
Limits to the sensitivity of a low noise compact atomic gravimeter
Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F. (2008) · Applied Physics B · doi:10.1007/s00340-008-3088-1 · Cited by 294
Determination of the Newtonian Gravitational Constant Using Atom Interferometry
Lamporesi, G., Bertoldi, A., Cacciapuoti, L., Prevedelli, M., & Tino, G. M. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.050801 · Cited by 277
Ferrari, G., Poli, N., Sorrentino, F., & Tino, G. M. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.060402 · Cited by 265
Compact cold atom gravimeter for field applications
Bidel, Y., Carraz, O., Charrière, R., Cadoret, M., Zahzam, N., & Bresson, A. (2013) · Applied Physics Letters · doi:10.1063/1.4801756 · Cited by 205
Self-citationOff-resonant Raman transition impact in an atom interferometer
Gauguet, A., Mehlstäubler, T. E., Lévèque, T., Gouët, J. L., Chaibi, W., Canuel, B., Clairon, A., dos Santos, F. P., & Landragin, A. (2008) · Physical Review A · doi:10.1103/physreva.78.043615 · Cited by 104
From optical lattice clocks to the measurement of forces in the Casimir regime
Wolf, P., Lemonde, P., Lambrecht, A., Bize, S., Landragin, A., & Clairon, A. (2007) · Physical Review A · doi:10.1103/physreva.75.063608 · Cited by 83
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Quantum superposition at the half-metre scale
Kovachy, T., Asenbaum, P., Overstreet, C., Donnelly, C. A., Dickerson, S. M., Sugarbaker, A., Hogan, J. M., & Kasevich, M. A. (2015) · Nature · doi:10.1038/nature16155 · Cited by 410
Taking atom interferometric quantum sensors from the laboratory to real-world applications
Bongs, K., Holynski, M., Vovrosh, J., Bouyer, P., Condon, G., Rasel, E., Schubert, C., Schleich, W. P., & Roura, A. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0117-4 · Cited by 382
Atom-Interferometric Test of the Equivalence Principle at the 10 − 12 Level
Asenbaum, P., Overstreet, C., Kim, M., Curti, J., & Kasevich, M. A. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.191101 · Cited by 331
Quantum Test of the Universality of Free Fall
Schlippert, D., Hartwig, J., Albers, H., Richardson, L. L., Schubert, C., Roura, A., Schleich, W. P., Ertmer, W., & Rasel, E. M. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.203002 · Cited by 331
Metadata
- Authors
- Bonnin, A., Zahzam, N., Bidel, Y., & Bresson, A.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2013-10-11
- Volume
- 88
- Issue
- 4
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1979694556
- Cited by
- 174
- References
- 21
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.