Enhanced effects of variation of the fundamental constants in laser interferometers and application to dark-matter detection
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We outline laser interferometer measurements to search for variation of the electromagnetic fine-structure constant $\ensuremath{\alpha}$ and particle masses (including a nonzero photon mass). We propose a strontium optical lattice clock---silicon single-crystal cavity interferometer as a small-scale platform for these measurements. Our proposed laser interferometer measurements, which may also be performed with large-scale gravitational-wave detectors, such as LIGO, Virgo, GEO600, or TAMA300, may be implemented as an extremely precise tool in the direct detection of scalar dark matter that forms an oscillating classical field or topological defects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DIRAC, P. A. M. (1937) · Nature · doi:10.1038/139323a0 · Cited by 1,495
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“[44] T.”
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431 · cited 1×
“[42] M.”
Searching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404 · cited 1×
“[9–31].”
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Flambaum, V. V., & Tedesco, A. F. (2006) · Physical Review C · doi:10.1103/physrevc.73.055501 · Cited by 163
Self-citationBerengut, J. C., Dzuba, V. A., Flambaum, V. V., & Porsev, S. G. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.210801 · Cited by 127
Self-citationNew Limits on Variation of the Fine-Structure Constant Using Atomic Dysprosium
Leefer, N., Weber, C. T. M., Cingöz, A., Torgerson, J. R., & Budker, D. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.060801 · Cited by 123
Hayes, A. C., & Friar, J. L. (2007) · Physics Letters B · doi:10.1016/j.physletb.2007.05.021 · Cited by 40
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Science with the Einstein Telescope: a comparison of different designs
Branchesi, M., Maggiore, M., Alonso, D., Badger, C., Banerjee, B., Beirnaert, F., Belgacem, E., Bhagwat, S., Boileau, G., Borhanian, S., et al. (2023) · Journal of Cosmology and Astroparticle Physics · doi:10.1088/1475-7516/2023/07/068 · Cited by 390
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
“There is great room for improvement on searches for ultralight DM taking advantage of state-of-theart optical clocks and ultrastable reference cavities [153].”
BackgroundFeebly-interacting particles: FIPs 2020 workshop report
Agrawal, P., Bauer, M., Beacham, J., Berlin, A., Boyarsky, A., Cebrian, S., Cid-Vidal, X., d’Enterria, D., De Roeck, A., Drewes, M., et al. (2021) · The European Physical Journal C · doi:10.1140/epjc/s10052-021-09703-7 · Cited by 275
Self-citationRiehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Metadata
- Authors
- Stadnik, Y. V., & Flambaum, V. V.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2016-06-24
- Volume
- 93
- Issue
- 6
- ISSN
- 0556-2791 (ISSN-L)
- 2469-9926
- 2469-9934
- OpenAlex
- W1960334103
- Cited by
- 138
- References
- 12
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.