Engineering interactions between superconducting qubits and phononic nanostructures
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Nanomechanical systems can support highly coherent microwave-frequency excitations at cryogenic temperatures. However, generating sufficient coupling between these devices and superconducting quantum circuits is challenging due to the vastly different length scales of acoustic and electromagnetic excitations. Here we demonstrate a general method for calculating piezoelectric interactions between quantum circuits and arbitrary phononic nanostructures. We illustrate our technique by studying the coupling between a transmon qubit and bulk acoustic-wave, Lamb-wave, and phononic crystal resonators, and show that very large coupling rates are possible in all three cases. Our results suggest a route to phononic circuits and systems that are nonlinear at the single-phonon level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent Josephson Qubit Suitable for Scalable Quantum Integrated Circuits
Barends, R., Kelly, J., Megrant, A., Sank, D., Jeffrey, E., Chen, Y., Yin, Y., Chiaro, B., Mutus, J., Neill, C., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.080502 · Cited by 779
Planar superconducting resonators with internal quality factors above one million
Megrant, A., Neill, C., Barends, R., Chiaro, B., Chen, Y., Feigl, L., Kelly, J., Lucero, E., Mariantoni, M., O’Malley, P. J. J., et al. (2012) · Applied Physics Letters · doi:10.1063/1.3693409 · Cited by 481
Balram, K. C., Davanço, M. I., Song, J. D., & Srinivasan, K. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.46 · Cited by 360
Cited by
Building a Fault-Tolerant Quantum Computer Using Concatenated Cat Codes
Chamberland, C., Noh, K., Arrangoiz-Arriola, P., Campbell, E. T., Hann, C. T., Iverson, J., Putterman, H., Bohdanowicz, T. C., Flammia, S. T., Keller, A., et al. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.010329 · Cited by 281
Self-citationNano-opto-electro-mechanical systems
Midolo, L., Schliesser, A., & Fiore, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-017-0039-1 · Cited by 276
Two-dimensional optomechanical crystal cavity with high quantum cooperativity
Ren, H., Matheny, M. H., MacCabe, G. S., Luo, J., Pfeifer, H., Mirhosseini, M., & Painter, O. (2020) · Nature Communications · doi:10.1038/s41467-020-17182-9 · Cited by 131
“[57] P.”
BackgroundLithium niobate piezo-optomechanical crystals
Jiang, W., Patel, R. N., Mayor, F. M., McKenna, T. P., Arrangoiz-Arriola, P., Sarabalis, C. J., Witmer, J. D., Van Laer, R., & Safavi-Naeini, A. H. (2019) · Optica · doi:10.1364/optica.6.000845 · Cited by 129
Self-citationThin-film quartz for high-coherence piezoelectric phononic crystal resonators
Emser, A. L., Metzger, C., Rose, B. C., & Lehnert, K. W. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.064032 · Cited by 8
Metadata
- Authors
- Arrangoiz-Arriola, P., & Safavi-Naeini, A. H.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2016-12-30
- Volume
- 94
- Issue
- 6
- ISSN
- 0556-2791 (ISSN-L)
- 2469-9926
- 2469-9934
- OpenAlex
- W2464730154
- Cited by
- 34
- References
- 3
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.