The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
New Limits on Coupling of Fundamental Constants to Gravity UsingSr87Optical Lattice Clocks
Open accessAbstract
The $^{1}S_{0}$-$^{3}P_{0}$ clock transition frequency ${\ensuremath{\nu}}_{\mathrm{Sr}}$ in neutral $^{87}\mathrm{Sr}$ has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years. The agreement on the $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ level makes ${\ensuremath{\nu}}_{\mathrm{Sr}}$ the best agreed-upon optical atomic frequency. We combine periodic variations in the $^{87}\mathrm{Sr}$ clock frequency with $^{199}\mathrm{Hg}^{+}$ and H-maser data to test local position invariance by obtaining the strongest limits to date on gravitational-coupling coefficients for the fine-structure constant $\ensuremath{\alpha}$, electron-proton mass ratio $\ensuremath{\mu}$, and light quark mass. Furthermore, after $^{199}\mathrm{Hg}^{+}$, $^{171}\mathrm{Yb}^{+}$, and H, we add $^{87}\mathrm{Sr}$ as the fourth optical atomic clock species to enhance constraints on yearly drifts of $\ensuremath{\alpha}$ and $\ensuremath{\mu}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Self-citationSr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Self-citationNew Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationSearch for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationLimit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
Cold atom clocks and applications
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Santos, F. P. D., Rosenbusch, P., et al. (2005) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/38/9/002 · Cited by 239
Self-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Sr87Lattice Clock with Inaccuracy below10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
Self-citationSystematic Study of theSr87Clock Transition in an Optical Lattice
Ludlow, A. D., Boyd, M. M., Zelevinsky, T., Foreman, S. M., Blatt, S., Notcutt, M., Ido, T., & Ye, J. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.033003 · Cited by 184
Self-citationFlambaum, V. V., & Tedesco, A. F. (2006) · Physical Review C · doi:10.1103/physrevc.73.055501 · Cited by 163
Self-citation
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
Theory and Experiment in Gravitational Physics
Will, C. M. (2018) · doi:10.1017/9781316338612 · Cited by 3,637
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationMicroresonator-Based Optical Frequency Combs
Kippenberg, T. J., Holzwarth, R., & Diddams, S. A. (2011) · Science · doi:10.1126/science.1193968 · Cited by 2,192
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Cold and ultracold molecules: science, technology and applications
Carr, L. D., DeMille, D., Krems, R. V., & Ye, J. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055049 · Cited by 1,330
Self-citationAn Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Self-citationVarying Constants, Gravitation and Cosmology
Uzan, J.-P. (2011) · Living Reviews in Relativity · doi:10.12942/lrr-2011-2 · Cited by 740
A steady-state superradiant laser with less than one intracavity photon
Bohnet, J. G., Chen, Z., Weiner, J. M., Meiser, D., Holland, M. J., & Thompson, J. K. (2012) · Nature · doi:10.1038/nature10920 · Cited by 528
The Confrontation between General Relativity and Experiment
Will, C. M. (2001) · Living Reviews in Relativity · doi:10.12942/lrr-2001-4 · Cited by 523
Quantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Self-citationSearching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
The Buffer Gas Beam: An Intense, Cold, and Slow Source for Atoms and Molecules
Hutzler, N. R., Lu, H.-I., & Doyle, J. M. (2012) · Chemical Reviews · doi:10.1021/cr200362u · Cited by 377
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
Self-citationA precision measurement of the gravitational redshift by the interference of matter waves
Müller, H., Peters, A., & Chu, S. (2010) · Nature · doi:10.1038/nature08776 · Cited by 311
Highly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Optical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Self-citationSpace-borne frequency comb metrology
Lezius, M., Wilken, T., Deutsch, C., Giunta, M., Mandel, O., Thaller, A., Schkolnik, V., Schiemangk, M., Dinkelaker, A., Kohfeldt, A., et al. (2016) · Optica · doi:10.1364/optica.3.001381 · Cited by 272
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Colloquium: Physics of optical lattice clocks
Derevianko, A., & Katori, H. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.331 · Cited by 253
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Self-citationA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Frequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
Self-citationNew Limits on Variation of the Fine-Structure Constant Using Atomic Dysprosium
Leefer, N., Weber, C. T. M., Cingöz, A., Torgerson, J. R., & Budker, D. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.060801 · Cited by 123
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Truppe, S., Hendricks, R. J., Tokunaga, S. K., Lewandowski, H. J., Kozlov, M. G., Henkel, C., Hinds, E. A., & Tarbutt, M. R. (2013) · Nature Communications · doi:10.1038/ncomms3600 · Cited by 97
Long term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Geopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
Sensitivity of hyperfine structure to nuclear radius and quark mass variation
Dinh, T. H., Dunning, A., Dzuba, V. A., & Flambaum, V. V. (2009) · Physical Review A · doi:10.1103/physreva.79.054102 · Cited by 46
Self-citationNakashima, M., Ichikawa, K., Nagata, R., & Yokoyama, J. (2010) · Journal of Cosmology and Astroparticle Physics · doi:10.1088/1475-7516/2010/01/030 · Cited by 34
Gyromagnetic factors and atomic clock constraints on the variation of fundamental constants
Luo, F., Olive, K. A., & Uzan, J.-P. (2011) · Physical Review D · doi:10.1103/physrevd.84.096004 · Cited by 31
Fundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Metadata
- Authors
- Blatt, S., Ludlow, A. D., Campbell, G. K., Thomsen, J. W., Zelevinsky, T., Boyd, M. M., Ye, J., Baillard, X., Fouché, M., Le Targat, R., Brusch, A., Lemonde, P., Takamoto, M., Hong, F.-L., Katori, H., & Flambaum, V. V.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2008-04-09
- Volume
- 100
- Issue
- 14
- Pages
- 140801-140801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2043307605
- Cited by
- 333
- References
- 21
- FWCI
- 20.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.