Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
Open accessThe DOI matches its Crossref record.
Abstract
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to $\ensuremath{\delta}\ensuremath{\nu}/\ensuremath{\nu}=\ifmmode\pm\else\textpm\fi{}8.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than $\ifmmode\pm\else\textpm\fi{}1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“ain and on deliberately varying the atom number. The strategies to reduce and evaluate the main frequency shifts and associated uncertainties, in quasi real-time for the main shifts, are described in [19, 17, 20, 21]. Last published accuracy budgets can be found in [17]. During the measurements reported in this Optica…”
BackgroundSelf-citationGuéna, J., Weyers, S., Abgrall, M., Grebing, C., Gerginov, V, Rosenbusch, P., Bize, S., Lipphardt, B., Denker, H., Quintin, N., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa65fe · Cited by 83
Self-citationDirect comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Self-citation
Metadata
- Authors
- Guéna, J., Li, R., Gibble, K., Bize, S., & Clairon, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-04-01
- Volume
- 106
- Issue
- 13
- Pages
- 130801-130801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1979613198
- Cited by
- 69
- References
- 0
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks. https://app.cochat.ai/papers/10.1103/physrevlett.106.130801
- The paper
- Guéna, J., Li, R., Gibble, K., Bize, S., & Clairon, A. (2011). Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks. Physical Review Letters. https://doi.org/10.1103/physrevlett.106.130801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.