Phase-Sensitive Cyclotron Frequency Measurements at Ultralow Energies
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A novel technique for a direct and coherent measurement of the modified cyclotron frequency of an ion in a Penning trap at energies close to the thermal cooling limit is presented. This allows a rapid and both precise and accurate determination of the free-space cyclotron frequency in real Penning traps despite the existence of electric and magnetic field imperfections and relativistic shifts. The demonstrated performance paves the way for considerably improved bound-state g-factor measurements on the 10 ppt level and mass measurements in the 1 ppt range and possibly below.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
Self-citationElectronicgFactor of Hydrogenlike OxygenO7+16
Verdú, J., Djekić, S., Stahl, S., Valenzuela, T., Vogel, M., Werth, G., Beier, T., Kluge, H.-J., & Quint, W. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.093002 · Cited by 251
Mode coupling in a Penning trap:π pulses and a classical avoided crossing
Cornell, E. A., Weisskoff, R. M., Boyce, K. R., & Pritchard, D. E. (1990) · Physical Review A · doi:10.1103/physreva.41.312 · Cited by 181
g Factor of Hydrogenlike Si13+28
(2011) · Physical Review Letters · doi:10.1103/physrevlett.107.023002 · Cited by 176
Self-citationUltrastable superconducting magnet system for a penning trap mass spectrometer
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149649 · Cited by 63
Determination of the g-Factor of Single Hydrogen-Like Ions by Mode Coupling in a Penning Trap
Verd?, J. L., Djekic, S., Stahl, S., Valenzuela, T., Vogel, M., Werth, G., Kluge, H.-J., & Quint, W. (2004) · Physica Scripta · doi:10.1238/physica.topical.112a00068 · Cited by 29
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
High-precision measurement of the atomic mass of the electron
Sturm, S., Köhler, F., Zatorski, J., Wagner, A., Harman, Z., Werth, G., Quint, W., Keitel, C. H., & Blaum, K. (2014) · Nature · doi:10.1038/nature13026 · Cited by 326
“The recent development of the “Pulse and Amplify” (PnA) technique [21] has enabled us to perform phase-sensitive measurements of the modified cyclotron frequency at lowest energies below the detection threshold of the image-current amplifier, a significant improvement compared to the established ‘pulse and probe’ tech…”
MethodSelf-citationElectron g‐factor determinations in Penning traps
Sturm, S., Werth, G., & Blaum, K. (2013) · Annalen der Physik · doi:10.1002/andp.201300052 · Cited by 33
Self-citationHigh-Precision Determination of g Factors and Masses of Ne209+ and Ne229+
Heiße, F., Door, M., Sailer, T., Filianin, P., Herkenhoff, J., König, C. M., Kromer, K., Lange, D., Morgner, J., Rischka, A., et al. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.253002 · Cited by 18
Self-citation
Metadata
- Authors
- Sturm, S., Wagner, A., Schabinger, B., & Blaum, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-09-28
- Volume
- 107
- Issue
- 14
- Pages
- 143003-143003
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2087435452
- Cited by
- 76
- References
- 7
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.