High-Accuracy Measurement of the Differential Scalar Polarizability of aSr+88Clock Using the Time-Dilation Effect
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report a high-accuracy measurement of the differential static scalar polarizability Δα(0) of the 5s(2)S(1/2)-4d(2)D(5/2) transition of the (88)Sr(+) ion. The high accuracy is obtained by comparing the micromotion-induced positive scalar Stark shift to the negative time-dilation shift. Measurement of the trap drive frequency where these shifts cancel is used to determine Δα(0) without the need to determine the electric field. Δα(0) is a critical parameter for the operation of frequency standards as it determines the blackbody radiation frequency shift coefficient, the largest source of uncertainty in the (88)Sr(+) ion clock. The measured value of Δα(0) is -4.7938(71) × 10(-40) J m(2)/V(2). Taking into account the dynamic correction, the blackbody shift at 300 K is 0.247,99(37) Hz. The contribution of the blackbody shift coefficient to the uncertainty of the ion standard has been reduced by a factor of 24, from 2 × 10(-17) to 8.3 × 10(-19). The revised total uncertainty of our reference standard is 1.2 × 10(-17), limited by the blackbody field evaluation. An additional benefit of the low uncertainty of Δα(0) is the ability to suppress, by a factor of about 200, the net micromotion frequency shifts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Highly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“2 × 10−17 (Dubé et al., 2014) inaccuracy and 3 × 10−17 reproducibility (Barwood et al.”
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
Metadata
- Authors
- Dubé, P., Madej, A. A., Tibbo, M., & Bernard, J. E.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2014-04-29
- Volume
- 112
- Issue
- 17
- Pages
- 173002-173002
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2066747114
- Cited by
- 106
- References
- 4
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Accuracy Measurement of the Differential Scalar Polarizability of aSr+88Clock Using the Time-Dilation Effect. https://app.cochat.ai/papers/10.1103/physrevlett.112.173002
- The paper
- Dubé, P., Madej, A. A., Tibbo, M., & Bernard, J. E. (2014). High-Accuracy Measurement of the Differential Scalar Polarizability of aSr+88Clock Using the Time-Dilation Effect. Physical Review Letters. https://doi.org/10.1103/physrevlett.112.173002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.