Cited by 137Advanced Frequency and Time StandardsScientific Measurement and Uncertainty EvaluationQuantum Information and Cryptography

Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty

Open access
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M. +2 more·2014·Physical Review Letters

Abstract

The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.113.260801

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These clocks are based on optical transitions, in which greater oscillation frequency leads to an increase of 10^5 in the quality factor of the transition and concomitant performance improvements.

    “These clocks are based on optical transitions, in which greater oscillation frequency leads to an increase of 10 5 in the quality factor of the transition and concomitant performance improvements 22 .”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. [16]I. Ushijima, M. Takamoto, M. Das, T. Ohkubo, and H. Katori, arXiv:1405.4071 (2014). · arXiv
  2. [17]J. Lodewyck, M. Zawada, L. Lorini, M. Gurov, and P. Lemonde, IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 59 , 411 (2012).
  3. [22]P. R. Bevington and D. K. Robinson, Data Reduction and Error Analysis (McGraw-Hill, New York, NY, 2003), 3rd ed.
  4. [27]A. Derevianko and M. Pospelov, arXiv:1311.1244 (2014). · arXiv
  5. [28]A. Arvanitaki, J. Huang, and K. V. Tilburg, arXiv:1405.2925 (2014). · arXiv

Cited by

Sorted by citations

Authors
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D.
Affiliations
National Institute of Standards and Technology (US)
Venue
Physical Review Letters
Published
2014-12-24
Volume
113
Issue
26
Pages
260801-260801
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W1754936697
Cited by
137
References
24
Citations by year
2026: 5 · 2025: 13 · 2024: 8 · 2023: 10 · 2022: 10 · 2021: 7 · 2020: 10 · 2019: 15 · 2018: 18 · 2017: 14 · 2016: 16 · 2015: 11
FWCI
6.80
Type
journal article
Language
en
Open access
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • National Institute of Standards and Technology
  • National Aeronautics and Space Administration
  • Defense Sciences Office, DARPA
  • DARPA QuASAR
  • DARPA PULSE
  • NRC-RAP
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
Keywords
blackbody radiation, Stark shift, atomic clocks, radiation shielding, room-temperature operation, clock uncertainty

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review