Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Open accessAbstract
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These clocks are based on optical transitions, in which greater oscillation frequency leads to an increase of 10^5 in the quality factor of the transition and concomitant performance improvements.
“These clocks are based on optical transitions, in which greater oscillation frequency leads to an increase of 10 5 in the quality factor of the transition and concomitant performance improvements 22 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Quantum information with Rydberg atoms
Saffman, M. E., Walker, T. G., & Mølmer, K. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.2313 · Cited by 2,796 · see citing works
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · see citing works
Evaluating the characteristics of multiwall carbon nanotubes
Lehman, J. H., Terrones, M., Mansfield, E., Hurst, K. E., & Meunier, V. (2011) · Carbon · doi:10.1016/j.carbon.2011.03.028 · Cited by 1,180 · see citing works
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · see citing works
An Atomic Clock with 10 <sup>–18</sup> Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · see citing works
Self-citationSr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554 · see citing works
Self-citationHunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522 · see citing works
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279 · see citing works
Spin- 1/2 Optical Lattice Clock
Lemke, N., Ludlow, A. D., Barber, Z. W., Fortier, T. M., Diddams, S. A., Jiang, Y., Jefferts, S. R., Heavner, T. P., Parker, T. E., & Oates, C. W. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274 · see citing works
Self-citationHigh-Accuracy Optical Clock Based on the Octupole Transition in Yb+171
Huntemann, N., Okhapkin, M. V., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241 · see citing works
A strontium lattice clock with 3 × 10<sup>−17</sup>inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182 · see citing works
Trapping of Neutral Mercury Atoms and Prospects for Optical Lattice Clocks
Hachisu, H., Miyagishi, K., Porsev, S. G., Derevianko, A., Ovsiannikov, V. D., Pal'chikov, V. G., Takamoto, M., & Katori, H. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.053001 · Cited by 182 · see citing works
Madej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155 · see citing works
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 153 · see citing works
Blackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, M. S., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140 · see citing works
High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock
Sherman, J. A., Lemke, N., Hinkley, N., Pizzocaro, M., Fox, R. W., Ludlow, A. D., & Oates, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153002 · Cited by 131 · see citing works
Self-citationEinstein Gravity Explorer–a medium-class fundamental physics mission
Schiller, S., Tino, G. M., Gill, P. R., Salomon, C., Sterr, U., Peik, E., Nevsky, A. Y., Görlitz, A., Švehla, D., Ferrari, G., et al. (2008) · Experimental Astronomy · doi:10.1007/s10686-008-9126-5 · Cited by 110 · see citing works
Dubé, P., Madej, A. A., Tibbo, M., & Bernard, J. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.173002 · Cited by 106 · see citing works
Observation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks
Lodewyck, J., Zawada, M., Lorini, L., Gurov, M., & Lemonde, P. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2209 · Cited by 72 · see citing works
Frequency Shift of the Cesium Clock Transition due to Blackbody Radiation
Angstmann, E., Dzuba, V. A., & Flambaum, V. V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.040802 · Cited by 69 · see citing works
Determination of the 5d6s 3D1 state lifetime and blackbody-radiation clock shift in Yb
Beloy, K., Sherman, J. A., Lemke, N., Hinkley, N., Oates, C. W., & Ludlow, A. D. (2012) · Physical Review A · doi:10.1103/physreva.86.051404 · Cited by 68 · see citing works
Self-citationYtterbium in Quantum Gases and Atomic Clocks: van der Waals Interactions and Blackbody Shifts
Safronova, M. S., Porsev, S. G., & Clark, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230802 · Cited by 51 · see citing works
Jefferts, S. R., Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, E. A., Ashby, N., Levi, F., Calonico, D., & Costanzo, G. A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.050801 · Cited by 36 · see citing works
Multiwall carbon nanotube absorber on a thin-film lithium niobate pyroelectric detector
Lehman, J. H., Hurst, K. E., Radojevic, A. M., et al. (2007) · Optics Letters · doi:10.1364/ol.32.000772 · Cited by 30 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 5
- [16]I. Ushijima, M. Takamoto, M. Das, T. Ohkubo, and H. Katori, arXiv:1405.4071 (2014). · arXiv
- [17]J. Lodewyck, M. Zawada, L. Lorini, M. Gurov, and P. Lemonde, IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 59 , 411 (2012).
- [22]P. R. Bevington and D. K. Robinson, Data Reduction and Error Analysis (McGraw-Hill, New York, NY, 2003), 3rd ed.
- [27]A. Derevianko and M. Pospelov, arXiv:1311.1244 (2014). · arXiv
- [28]A. Arvanitaki, J. Huang, and K. V. Tilburg, arXiv:1405.2925 (2014). · arXiv
Cited by
Sorted by citations
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385 · see citing works
Self-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · see citing works
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727 · see citing works
Self-citationHuntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · see citing works
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324 · see citing works
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263 · see citing works
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221 · see citing works
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85 · see citing works
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82 · see citing works
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64 · see citing works
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26 · see citing works
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23 · see citing works
Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock
Beloy, K., Zhang, X., McGrew, W. F., Hinkley, N., Yoon, T. H., Nicolodi, D., Fasano, R. J., Schäffer, S. A., Brown, R. C., & Ludlow, A. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.183201 · Cited by 20 · see citing works
Self-citationProgress on the optical lattice clock
Ludlow, A. D., & Ye, J. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.008 · Cited by 14 · see citing works
Self-citation
- Authors
- Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D.
- Affiliations
- National Institute of Standards and Technology (US)
- ORCID
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2014-12-24
- Volume
- 113
- Issue
- 26
- Pages
- 260801-260801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1754936697
- Cited by
- 137
- References
- 24
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 8 · 2023: 10 · 2022: 10 · 2021: 7 · 2020: 10 · 2019: 15 · 2018: 18 · 2017: 14 · 2016: 16 · 2015: 11
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Physical Review Letters (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Institute of Standards and Technology
- National Aeronautics and Space Administration
- Defense Sciences Office, DARPA
- DARPA QuASAR
- DARPA PULSE
- NRC-RAP
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
- Keywords
- blackbody radiation, Stark shift, atomic clocks, radiation shielding, room-temperature operation, clock uncertainty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review