Two-Dimensional Correlation of Isotropic and Directional Diffusion Using NMR
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Diffusion nuclear magnetic resonance (NMR) is a powerful technique for studying porous media, but yields ambiguous results when the sample comprises multiple regions with different pore sizes, shapes, and orientations. Inspired by solid-state NMR techniques for correlating isotropic and anisotropic chemical shifts, we propose a diffusion NMR method to resolve said ambiguity. Numerical data inversion relies on sparse representation of the data in a basis of radial and axial diffusivities. Experiments are performed on a composite sample with a cell suspension and a liquid crystal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
Nonparametric estimates of standard error: The jackknife, the bootstrap and other methods
EFRON, B. (1981) · Biometrika · doi:10.1093/biomet/68.3.589 · Cited by 1,399
Jeurissen, B., Leemans, A., Tournier, J., Jones, D. K., & Sijbers, J. (2013) · Human Brain Mapping · doi:10.1002/hbm.22099 · Cited by 1,088
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849
Assaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Sundgren, P. C., & Nilsson, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.053 · Cited by 200
Lampinen, B., Szczepankiewicz, F., Lätt, J., Knutsson, L., Mårtensson, J., Björkman-Burtscher, I. M., van Westen, D., Sundgren, P. C., Ståhlberg, F., & Nilsson, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120338 · Cited by 38
Metadata
- Authors
- de Almeida Martins, J. P., & Topgaard, D.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2016-02-23
- Volume
- 116
- Issue
- 8
- Pages
- 087601-087601
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2306358050
- Cited by
- 76
- References
- 10
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.