The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Squeezed-light–enhanced polarization interferometer
Abstract
Enhancement of the sensitivity of a polarization interferometer beyond the limit set by vacuum fluctuations of the electromagnetic field has been obtained with use of squeezed light generated by a ${\mathrm{KTiOPO}}_{4}$ optical parametric amplifier. The increase in signal-to-noise ratio relative to the shot-noise limit is 2 dB. The corresponding improvement in the response time of the interferometer is measured to be a factor of 1.6.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Generation of Squeezed States by Parametric Down Conversion
Wu, L.-A., Kimble, H. J., Hall, J. L., & Wu, H. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.2520 · Cited by 1,653
SU(2) and SU(1,1) interferometers
Yurke, B., McCall, S. L., & Klauder, J. R. (1986) · Physical Review A · doi:10.1103/physreva.33.4033 · Cited by 1,366
Self-citationPrecision measurement beyond the shot-noise limit
Xiao, M., Wu, L.-A., & Kimble, H. J. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.278 · Cited by 723
Picosecond electro-optic sampling system
Valdmanis, J. A., Mourou, G., & Gabel, C. W. (1982) · Applied Physics Letters · doi:10.1063/1.93485 · Cited by 359
Squeezed states in phase-sensing interferometers
Bondurant, R. S., & Shapiro, J. H. (1984) · Physical Review D · doi:10.1103/physrevd.30.2548 · Cited by 298
Gravitational-wave research: Current status and future prospects
Thorne, K. S. (1980) · Reviews of Modern Physics · doi:10.1103/revmodphys.52.285 · Cited by 181
Sanders, G. A., Prentiss, M. G., & Ezekiel, S. (1981) · Optics Letters · doi:10.1364/ol.6.000569 · Cited by 156
Measurement of amplitude probability distributions for photon-number-operator eigenstates
Yurke, B., & Stoler, D. (1987) · Physical Review A · doi:10.1103/physreva.36.1955 · Cited by 62
Self-citationSqueezed-state-enhanced frequency-modulation spectroscopy
Yurke, B., & Whittaker, E. A. (1987) · Optics Letters · doi:10.1364/ol.12.000236 · Cited by 38
Self-citationPhoton noise reduction and coherence properties of squeezed fields
Heidmann, A., Reynaud, S., & Cohen-Tannoudji, C. N. (1984) · Optics Communications · doi:10.1016/0030-4018(85)90218-4 · Cited by 24
Cited by
Quantum estimation for quantum technology
PARIS, M. G. A. (2009) · International Journal of Quantum Information · doi:10.1142/s0219749909004839 · Cited by 1,632
Smithey, D. T., Beck, M., Raymer, M. G., & Faridani, A. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1244 · Cited by 1,538
Squeezed atomic states and projection noise in spectroscopy
Wineland, D. J., Bollinger, J. J., Itano, W. M., & Heinzen, D. J. (1994) · Physical Review A · doi:10.1103/physreva.50.67 · Cited by 1,166
Realization of the Einstein-Podolsky-Rosen paradox for continuous variables
Ou, Z. Y., Pereira, S. F., Kimble, H. J., & Peng, K. C. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.3663 · Cited by 1,151
Spin squeezing and reduced quantum noise in spectroscopy
Wineland, D. J., Bollinger, J. J., Itano, W. M., Moore, F. L., & Heinzen, D. J. (1992) · Physical Review A · doi:10.1103/physreva.46.r6797 · Cited by 1,135
Metadata
- Authors
- Grangier, P., Slusher, R. E., Yurke, B., & LaPorta, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1987-11-09
- Volume
- 59
- Issue
- 19
- Pages
- 2153-2156
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2074638350
- Cited by
- 493
- References
- 12
- FWCI
- 17.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.