Phase-Locked High-Order Harmonic Sources
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We demonstrate that two harmonic sources generated independently in a xenon gas jet using the same picosecond Nd:YAG laser are locked in phase. The experiment is performed by separating a laser beam into two parallel beams focused at different locations under the nozzle of a gas jet, and therefore producing two independent sources of harmonic radiation, and studying the pattern obtained in the far field when the radiations from these sources interfere. A high and robust fringe visibility is obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced High-Harmonic Generation Using 25 fs Laser Pulses
Zhou, J., Peatross, J., Murnane, M. M., Kapteyn, H. C., & Christov, I. P. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.752 · Cited by 353
Cited by
High harmonic interferometry of multi-electron dynamics in molecules
Smirnova, O., Mairesse, Y., Patchkovskii, S., Dudovich, N., Villeneuve, D., Corkum, P., & Ivanov, M. Y. (2009) · Nature · doi:10.1038/nature08253 · Cited by 1,114
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Self-citationGeneration of Coherent Soft X Rays at 2.7 nm Using High Harmonics
Chang, Z., Rundquist, A., Wang, H., Murnane, M. M., & Kapteyn, H. C. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2967 · Cited by 752
Measurement and laser control of attosecond charge migration in ionized iodoacetylene
Kraus, P. M., Mignolet, B., Baykusheva, D., Rupenyan, A., Horný, L., Penka, E. F., Grassi, G., Tolstikhin, O. I., Schneider, J., Jensen, F., et al. (2015) · Science · doi:10.1126/science.aab2160 · Cited by 628
Jones, R. J., Moll, K. D., Thorpe, M. J., & Ye, J. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.193201 · Cited by 500
Metadata
- Authors
- Zerne, R., Altucci, C., Bellini, M., Gaarde, M. B., Hänsch, T. W., L'Huillier, A., Lyngå, C., & Wahlström, C.-G.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1997-08-11
- Volume
- 79
- Issue
- 6
- Pages
- 1006-1009
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1967387252
- Cited by
- 117
- References
- 1
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.