The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Phase-Coherent Measurement of the Hydrogen1S−2STransition Frequency with an Optical Frequency Interval Divider Chain
Abstract
We have measured the absolute frequency of the hydrogen $1S\ensuremath{-}2S$ two-photon resonance with an accuracy of 3.4 parts in ${10}^{13}$ by comparing it with the $28\mathrm{th}$ harmonic of a methane-stabilized $3.39\ensuremath{\mu}\mathrm{m}$ He-Ne laser. A frequency mismatch of 2.1 THz at the $7\mathrm{th}$ harmonic is bridged with a phase-locked chain of five optical frequency interval dividers. From the measured frequency ${f}_{1S\ensuremath{-}2S}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}2466061413187.34(84)\mathrm{kHz}$ and published data of other authors we derive precise new values of the Rydberg constant, ${R}_{\ensuremath{\infty}}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}10973731.568639(91){\mathrm{m}}^{\ensuremath{-}1}$ and of the Lamb shift of the $1S$ ground state, ${L}_{1S}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}8172.876(29)\mathrm{MHz}$. These are now the most accurate values available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simon, G. G., Schmitt, C., Borkowski, F., & Walther, V. H. (1980) · Nuclear Physics A · doi:10.1016/0375-9474(80)90104-9 · Cited by 454
Dispersion-theoretical analysis of the nucleon electromagnetic form factors
Mergell, P., Meißner, U.-G., & Drechsel, D. (1996) · Nuclear Physics A · doi:10.1016/0375-9474(95)00339-8 · Cited by 380
Frequency of the Hydrogen Maser
ESSEN, L., DONALDSON, R. W., BANGHAM, M. J., & HOPE, E. G. (1971) · Nature · doi:10.1038/229110a0 · Cited by 315
de Beauvoir, B., Nez, F., Julien, L., Cagnac, B., Biraben, F., Touahri, D., Hilico, L., Acef, O., Clairon, A., & Zondy, J. J. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.440 · Cited by 207
Farnham, D. L., Van Dyck, R. S., & Schwinberg, P. B. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.3598 · Cited by 198
Telle, H. R., Meschede, D., & Hänsch, T. W. (1990) · Optics Letters · doi:10.1364/ol.15.000532 · Cited by 192
Self-citationHigh Resolution Spectroscopy of the Hydrogen Atom: Determination of the 1S Lamb Shift
Bourzeix, S., de Beauvoir, B., Nez, F., Plimmer, M. D., Tomasi, F. D., Julien, L., Biraben, F., & Stacey, D. N. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.384 · Cited by 127
Precise Optical Measurement of Lamb Shifts in Atomic Hydrogen
Berkeland, D. J., Hinds, E. A., & Boshier, M. G. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.2470 · Cited by 124
New Value of the α3 Electron Anomalous Magnetic Moment
Kinoshita, T. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4728 · Cited by 112
Weitz, M., Huber, A., Schmidt‐Kaler, F., Leibfried, D. G., Vassen, W., Zimmermann, C., Pachucki, K., Hänsch, T. W., Julien, L., & Biraben, F. (1995) · Physical Review A · doi:10.1103/physreva.52.2664 · Cited by 98
Self-citation
Cited by
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Self-citationCODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Dörner, R., Mergel, V., Jagutzki, O., Spielberger, L., Ullrich, J., Moshammer, R., & Schmidt-Böcking, H. (2000) · Physics Reports · doi:10.1016/s0370-1573(99)00109-x · Cited by 1,406
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Self-citationColloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Self-citationAbsolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
Self-citationCODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
Bose-Einstein Condensation of Atomic Hydrogen
Fried, D. G., Killian, T. C., Willmann, L., Landhuis, D., Moss, S. C., Kleppner, D., & Greytak, T. J. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.3811 · Cited by 750
Optical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 714
Self-citationCODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
New Determination of the Fine Structure Constant and Test of the Quantum Electrodynamics
Bouchendira, R., Cladé, P., Guellati-Khélifa, S., Nez, F., & Biraben, F. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.080801 · Cited by 568
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationMeasuring the frequency of light with mode-locked lasers
Reichert, J., Holzwarth, R., Udem, T., & Hänsch, T. W. (1999) · Optics Communications · doi:10.1016/s0030-4018(99)00491-5 · Cited by 473
Self-citationAccurate measurement of large optical frequency differences with a mode-locked laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Optics Letters · doi:10.1364/ol.24.000881 · Cited by 418
Self-citationQuinn, T. J. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/316 · Cited by 409
Frontiers in Ultrashort Pulse Generation: Pushing the Limits in Linear and Nonlinear Optics
Steinmeyer, G., Sutter, D. H., Gallmann, L., Matuschek, N., & Keller, U. (1999) · Science · doi:10.1126/science.286.5444.1507 · Cited by 397
Precision physics of simple atoms: QED tests, nuclear structure and fundamental constants
Karshenboim, S. G. (2005) · Physics Reports · doi:10.1016/j.physrep.2005.08.008 · Cited by 383
CPTand Lorentz Tests in Hydrogen and Antihydrogen
Bluhm, R., Kostelecký, V. A., & Russell, N. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.2254 · Cited by 337
Space-Time Variation of Physical Constants and Relativistic Corrections in Atoms
Dzuba, V. A., Flambaum, V. V., & Webb, J. K. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.888 · Cited by 308
Signatures in the Planck regime
Hossenfelder, S., Bleicher, M., Hofmann, S., Ruppert, J., Scherer, S., & Stöcker, H. (2003) · Physics Letters B · doi:10.1016/j.physletb.2003.09.040 · Cited by 305
Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., et al. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.711 · Cited by 292
Optical frequency synthesis based on mode-locked lasers
Cundiff, S. T., Ye, J., & Hall, J. L. (2001) · Review of Scientific Instruments · doi:10.1063/1.1400144 · Cited by 261
Metadata
- Authors
- Udem, T., Huber, A., Gross, B., Reichert, J., Prevedelli, M., Weitz, M., & Hänsch, T. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1997-10-06
- Volume
- 79
- Issue
- 14
- Pages
- 2646-2649
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2051250438
- Cited by
- 357
- References
- 11
- FWCI
- 22.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.