The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Demonstration of Dispersion-Canceled Quantum-Optical Coherence Tomography
Open accessAbstract
We present an experimental demonstration of quantum-optical coherence tomography. The technique makes use of an entangled twin-photon light source to carry out axial optical sectioning. It is compared to conventional optical coherence tomography. The immunity of the quantum version to dispersion, as well as a factor of 2 enhancement in resolution, is experimentally demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Measurement of subpicosecond time intervals between two photons by interference
Hong, C. K., Ou, Z. Y., & Mandel, L. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2044 · Cited by 4,369
(2016) · Optochemical Nanosensors · doi:10.1201/b13065-1 · Cited by 3,707
Saleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Self-citationOptical Coherence and Quantum Optics
Mandel, L., Wolf, E., & Meystre, P. (1996) · American Journal of Physics · doi:10.1119/1.18450 · Cited by 2,414
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Optical coherence tomography (OCT): a review
Schmitt, J. M. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796348 · Cited by 1,188
Optical coherence tomography in dermatology: a review
Welzel, J. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001001.x · Cited by 621
Submicrometer axial resolution optical coherence tomography
Povazay, B., Bizheva, K., Unterhuber, A., Hermann, B., Sattmann, H., Fercher, A. F., Drexler, W., Apolonski, A., Wadsworth, W. J., Knight, J. C., et al. (2002) · Optics Letters · doi:10.1364/ol.27.001800 · Cited by 480
Nonlocal cancellation of dispersion
Franson, J. D. (1992) · Physical Review A · doi:10.1103/physreva.45.3126 · Cited by 290
Dispersion cancellation in a measurement of the single-photon propagation velocity in glass
Steinberg, A. M., Kwiat, P. G., & Chiao, R. Y. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.2421 · Cited by 274
Quantum-optical coherence tomography with dispersion cancellation
Abouraddy, A. F., Nasr, M. B., Saleh, B. E. A., Sergienko, A. V., & Teich, M. C. (2002) · Physical Review A · doi:10.1103/physreva.65.053817 · Cited by 270
Self-citationBrezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1997) · Heart · doi:10.1136/hrt.77.5.397 · Cited by 241
Steinberg, A. M., Kwiat, P. G., & Chiao, R. Y. (1992) · Physical Review A · doi:10.1103/physreva.45.6659 · Cited by 202
Dispersion effects in partial coherence interferometry: implications for intraocular ranging
Hitzenberger, C. K. F., Baumgartner, A., Drexler, W., & FERCHER, A. F. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429900 · Cited by 116
Fourth-order interference of joint single-photon wave packets in lossless optical systems
Campos, R. A., Saleh, B. E. A., & Teich, M. C. (1990) · Physical Review A · doi:10.1103/physreva.42.4127 · Cited by 98
Self-citationDispersion compensation for optical coherence tomography depth-scan signals by a numerical technique
FERCHER, A. F., Hitzenberger, C. K. F., Sticker, M., Zawadzki, R. J., Karamata, B., & Lasser, T. (2002) · Optics Communications · doi:10.1016/s0030-4018(02)01137-9 · Cited by 67
Nonlocal cancellation of dispersive broadening in Mach-Zehnder interferometers
Larchuk, T. S., Teich, M. C., & Saleh, B. E. A. (1995) · Physical Review A · doi:10.1103/physreva.52.4145 · Cited by 40
Self-citation
Cited by
Non-invasive imaging through opaque scattering layers
Bertolotti, J., van Putten, E. G., Blum, C., Lagendijk, A., Vos, W. L., & Mosk, A. P. (2012) · Nature · doi:10.1038/nature11578 · Cited by 1,183
Quantum optical metrology – the lowdown on high-N00N states
Dowling, J. P. (2008) · Contemporary Physics · doi:10.1080/00107510802091298 · Cited by 894
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Exploiting chemistry and molecular systems for quantum information science
Wasielewski, M. R., Forbes, M. D. E., Frank, N. L., Kowalski, K., Scholes, G. D., Yuen-Zhou, J., Baldo, M. A., Freedman, D. E., Goldsmith, R. H., Goodson, T., et al. (2020) · Nature Reviews Chemistry · doi:10.1038/s41570-020-0200-5 · Cited by 568
Quantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Metadata
- Authors
- Nasr, M. B., Saleh, B. E. A., Sergienko, A. V., & Teich, M. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-08-22
- Volume
- 91
- Issue
- 8
- Pages
- 083601-083601
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2090044312
- Cited by
- 337
- References
- 19
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.