The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Limit on the Present Temporal Variation of the Fine Structure Constant
Open accessAbstract
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant $\ensuremath{\alpha}$ in a model-independent way without assumptions on constancy or variability of other parameters, allowing tests of the consequences of unification theories. We have measured an optical transition frequency at 688 THz in $^{171}\mathrm{Y}\mathrm{b}^{+}$ with a cesium atomic clock at 2 times separated by 2.8 yr and find a value for the fractional variation of the frequency ratio ${f}_{\mathrm{Y}\mathrm{b}}/{f}_{\mathrm{C}\mathrm{s}}$ of $(\ensuremath{-}1.2\ifmmode\pm\else\textpm\fi{}4.4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}\text{ }{\mathrm{y}\mathrm{r}}^{\ensuremath{-}1}$, consistent with zero. Combined with recently published values for the constancy of other transition frequencies this measurement sets an upper limit on the present variability of $\ensuremath{\alpha}$ at the level of $2.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}\text{ }{\mathrm{y}\mathrm{r}}^{\ensuremath{-}1}$ $(1\ensuremath{\sigma})$, corresponding so far to the most stringent limit from laboratory experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Blatt, J. M., & Weisskopf, V. F. (1979) · Springer eBooks · doi:10.1007/978-1-4612-9959-2 · Cited by 2,595
The fundamental constants and their variation: observational and theoretical status
Uzan, J.-P. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.403 · Cited by 1,162
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Further evidence for a variable fine-structure constant from Keck/HIRES QSO absorption spectra
Murphy, M. T., Webb, J. K., & Flambaum, V. V. (2003) · Monthly Notices of the Royal Astronomical Society · doi:10.1046/j.1365-8711.2003.06970.x · Cited by 514
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
The Oklo bound on the time variation of the fine-structure constant revisited
Damour, T., & Dyson, F. (1996) · Nuclear Physics B · doi:10.1016/s0550-3213(96)00467-1 · Cited by 374
Time Variation of the Fundamental "Constants" and Kaluza-Klein Theories
Marciano, W. J. (1984) · Physical Review Letters · doi:10.1103/physrevlett.52.489 · Cited by 353
Srianand, R., Chand, H., Petitjean, P., & Aracil, B. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.121302 · Cited by 335
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Atomic Clocks and Variations of the Fine Structure Constant
Prestage, J. D., Tjoelker, R. L., & Maleki, L. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3511 · Cited by 298
Dzuba, V. A., Flambaum, V. V., & Webb, J. K. (1999) · Physical Review A · doi:10.1103/physreva.59.230 · Cited by 293
Direct test of the constancy of fundamental nuclear constants
SHLYAKHTER, A. I. (1976) · Nature · doi:10.1038/264340a0 · Cited by 269
Absolute Frequency Measurements of theHg+and Ca Optical Clock Transitions with a Femtosecond Laser
Udem, T., Diddams, S. A., Vogel, K. R., Oates, C. W., Curtis, E. A., Lee, W. D., Itano, W. M., Drullinger, R. E., Bergquist, J. C., & Hollberg, L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4996 · Cited by 260
Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock
Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150802 · Cited by 249
The cosmological evolution of the nucleon mass and the electroweak coupling constants
Calmet, X., & Fritzsch, H. (2002) · The European Physical Journal C · doi:10.1007/s10052-002-0976-0 · Cited by 209
Implications of gauge unification for time variation of the fine structure constant
Langacker, P., Segrè, G., & Strassler, M. J. (2002) · Physics Letters B · doi:10.1016/s0370-2693(02)01189-9 · Cited by 193
Probing the variability of the fine-structure constant with the VLT UVES
Quast, R., Reimers, D., & Levshakov, S. A. (2003) · Springer Link (Chiba Institute of Technology) · doi:10.1051/0004-6361:20040013/pdf · Cited by 167
Probing the variability of the fine-structure constant with the VLT/UVES
Quast, R., Reimers, D., & Levshakov, S. A. (2004) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20040013 · Cited by 163
Some possibilities for laboratory searches for variations of fundamental constants
Karshenboim, S. G. (2000) · Canadian Journal of Physics · doi:10.1139/p00-045 · Cited by 135
Self-citationProceedings of the 1996 IEEE International Frequency Control Symposium
Ultrasonics, F. I. (1996) · Cited by 130
Stenger, J., Tamm, C., Haverkamp, N., Weyers, S., & Telle, H. R. (2001) · Optics Letters · doi:10.1364/ol.26.001589 · Cited by 129
Self-citationAstrophysics, Clocks and Fundamental Constants
Murphy, M. T., Flambaum, V. V., Webb, J. K., Dzuba, V. V., PROCHASKA, J., & Wolfe, A. M. (2004) · Lecture notes in physics · doi:10.1007/b13178 · Cited by 107
Spectroscopy of the electric-quadrupole transition 2S1/2(F=0)–2D3/2(F=2) in trapped 171Yb+
Tamm, C., Engelke, D., & Bühner, V. (2000) · Physical Review A · doi:10.1103/physreva.61.053405 · Cited by 98
Self-citationCaesium atomic clocks: function, performance and applications
Bauch, A. (2003) · Measurement Science and Technology · doi:10.1088/0957-0233/14/8/301 · Cited by 97
Dzuba, V. A., Flambaum, V. V., & Marchenko, M. V. (2003) · Physical Review A · doi:10.1103/physreva.68.022506 · Cited by 92
Constants and Variations: From Alpha to Omega
Barrow, J. D. (2003) · Astrophysics and Space Science · doi:10.1023/a:1022571927342 · Cited by 32
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
Theory and Experiment in Gravitational Physics
Will, C. M. (2018) · doi:10.1017/9781316338612 · Cited by 3,637
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationThe Confrontation between General Relativity and Experiment
Will, C. M. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-3 · Cited by 1,606
Cold and ultracold molecules: science, technology and applications
Carr, L. D., DeMille, D., Krems, R. V., & Ye, J. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055049 · Cited by 1,330
Metadata
- Authors
- Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2004-10-18
- Volume
- 93
- Issue
- 17
- Pages
- 170801-170801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2145008602
- Cited by
- 282
- References
- 28
- FWCI
- 23.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.