Frequency Shift of the Cesium Clock Transition due to Blackbody Radiation
Open accessThe DOI matches its Crossref record.
Abstract
We perform ab initio calculations of the frequency shift induced by a static electric field on the cesium clock hyperfine transition. The calculations are used to find the frequency shifts due to blackbody radiation. Our result [$\ensuremath{\delta}\ensuremath{\nu}/{E}^{2}=\ensuremath{-}2.26(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}\text{ }\text{ }\mathrm{Hz}/(\mathrm{V}/\mathrm{m}{)}^{2}$] is in good agreement with early measurements and ab initio calculations performed in other groups. We present arguments against recent claims that the actual value of the effect might be smaller. The difference ($\ensuremath{\sim}10%$) between ab initio and semiempirical calculations is due to the contribution of the continuum spectrum in the sum over intermediate states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
First accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82
Metadata
- Authors
- Angstmann, E. J., Dzuba, V. A., & Flambaum, V. V.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-07-27
- Volume
- 97
- Issue
- 4
- Pages
- 040802-040802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2067406860
- Cited by
- 69
- References
- 0
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Shift of the Cesium Clock Transition due to Blackbody Radiation. https://app.cochat.ai/papers/10.1103/physrevlett.97.040802
- The paper
- Angstmann, E. J., Dzuba, V. A., & Flambaum, V. V. (2006). Frequency Shift of the Cesium Clock Transition due to Blackbody Radiation. Physical Review Letters. https://doi.org/10.1103/physrevlett.97.040802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.