The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Single-photon detection by rod cells of the retina
Abstract
At low light levels, the visual system detects and counts photon absorptions with a reliability close to limits set by statistical fluctuations in the number of absorbed photons. Thus the rod photoreceptors that provide the input signals to the dark-adapted visual system act as nearly perfect photon counters. This elegant performance is possible because light detection in the rods satisfies four functional requirements: high quantum efficiency, sufficient amplification to produce a measurable response, low dark noise, and low trial-to-trial variability in the elementary response. The rod meets these requirements using biochemical reactions rather than the solid-state reactions of silicon detectors, yet its performance equals or exceeds that of man-made detectors in several ways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Induction by cyclic GMP of cationic conductance in plasma membrane of retinal rod outer segment
Fesenko, E. E., Kolesnikov, S. S., & Lyubarsky, A. L. (1985) · Nature · doi:10.1038/313310a0 · Cited by 1,211
Hecht, S., Shlaer, S., & Pirenne, M. H. (1942) · Journal of General Physiology · doi:10.1085/jgp.25.6.819 · Cited by 1,122
Responses of retinal rods to single photons.
Baylor, D. A., Lamb, T. D., & Yau, K. W. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012716 · Cited by 992
Self-citationThe photocurrent, noise and spectral sensitivity of rods of the monkey Macaca fascicularis.
Baylor, D. A., Nunn, B. J., & Schnapf, J. L. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015518 · Cited by 692
Self-citationAmplification and kinetics of the activation steps in phototransduction
Pugh, E. N., & Lamb, T. D. (1993) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(93)90038-h · Cited by 648
Cyclic GMP-Activated Conductance of Retinal Photoreceptor Cells
Yau, K. W., & Baylor, D. A. (1989) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.12.030189.001445 · Cited by 595
Self-citationDark Current and Photocurrent in Retinal Rods
Hagins, W. A., Penn, R. D., & Yoshikami, S. (1970) · Biophysical Journal · doi:10.1016/s0006-3495(70)86308-1 · Cited by 556
Two components of electrical dark noise in toad retinal rod outer segments.
Baylor, D. A., Matthews, G., & Yau, K. W. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013529 · Cited by 468
Self-citationRetinal Noise and Absolute Threshold
Barlow, H. B. (1956) · Journal of the Optical Society of America · doi:10.1364/josa.46.000634 · Cited by 439
Calcium and light adaptation in retinal rods and cones
Nakatani, K., & Yau, K.-W. (1988) · Nature · doi:10.1038/334069a0 · Cited by 386
Photoreceptor light adaptation is mediated by cytoplasmic calcium concentration
Matthews, H. R., Murphy, R. L. W., Fain, G. L., & Lamb, T. D. (1988) · Nature · doi:10.1038/334067a0 · Cited by 352
Regulation of sensitivity in vertebrate rod photoreceptors by calcium
Koutalos, Y., & Yau, K.-W. (1996) · Trends in Neurosciences · doi:10.1016/0166-2236(96)89624-x · Cited by 238
Millisecond activation of transducin in the cyclic nucleotide cascade of vision
Vuong, T. M., Chabre, M., & Stryer, L. (1984) · Nature · doi:10.1038/311659a0 · Cited by 211
Molecular origin of continuous dark noise in rod photoreceptors
Rieke, F., & Baylor, D. A. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79448-1 · Cited by 183
Self-citationCalcium and magnesium fluxes across the plasma membrane of the toad rod outer segment.
Nakatani, K., & Yau, K. W. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp016942 · Cited by 177
Karpen, J. W., Zimmerman, A. L., Stryer, L., & Baylor, D. A. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.4.1287 · Cited by 172
Self-citationSakitt, B. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009838 · Cited by 171
INTERMITTENT STIMULATION BY LIGHT
Hecht, S., & Verrijp, C. D. (1933) · The Journal of General Physiology · doi:10.1085/jgp.17.2.251 · Cited by 115
The cGMP-phosphodiesterase and its contribution to sensitivity regulation in retinal rods
Koutalos, Y. (1995) · The Journal of General Physiology · doi:10.1085/jgp.106.5.891 · Cited by 108
INTERMITTENT STIMULATION BY LIGHT
Hecht, S., & Wolf, E. (1932) · The Journal of General Physiology · doi:10.1085/jgp.15.4.369 · Cited by 92
Temporal filtering in retinal bipolar cells. Elements of an optimal computation?
Bialek, W., & Owen, W. G. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82463-2 · Cited by 68
Sources of noise in photoreceptor transduction
Lamb, T. D. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002295 · Cited by 31
Cited by
Training Spiking Neural Networks Using Lessons From Deep Learning
Eshraghian, J. K., Ward, M., Neftci, E. O., Wang, X., Lenz, G., Dwivedi, G., Bennamoun, M., Jeong, D. S., & Lu, W. D. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3308088 · Cited by 782
Probing the Limits to Positional Information
Gregor, T., Tank, D. W., Wieschaus, E. F., & Bialek, W. (2007) · Cell · doi:10.1016/j.cell.2007.05.025 · Cited by 692
Slowed recovery of rod photoresponse in mice lacking the GTPase accelerating protein RGS9-1
Chen, C.-K., Burns, M. E., He, W., Wensel, T. G., Baylor, D. A., & Simon, M. I. (2000) · Nature · doi:10.1038/35000601 · Cited by 527
Self-citationQuantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Physical limits to biochemical signaling
Bialek, W., & Setayeshgar, S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504321102 · Cited by 443
Metadata
- Authors
- Rieke, F., & Baylor, D. A.
- Venue
- Reviews of Modern Physics
- Publisher
- American Physical Society (APS)
- Published
- 1998-07-01
- Volume
- 70
- Issue
- 3
- Pages
- 1027-1036
- ISSN
- 0034-6861 (ISSN-L)
- 1539-0756
- OpenAlex
- W2120277394
- Cited by
- 263
- References
- 22
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.