Scatterless hybrid metal–single-crystal slit for small-angle X-ray scattering and high-resolution X-ray diffraction
The DOI matches its Crossref record.
Abstract
A simple hybrid design has been developed to produce practically scatterless aperture slits for small-angle X-ray scattering and high-resolution X-ray diffraction. The hybrid slit consists of a rectangular single-crystal substrate (e.g.Si or Ge) bonded to a high-density metal base with a large taper angle (> 10°). The beam-defining single-crystal tip is oriented far from any Bragg peak position with respect to the incident beam and hence produces none of the slit scattering commonly associated with conventional metal slits. It has been demonstrated that the incorporation of the scatterless slits leads to a much simplified design in small-angle X-ray scattering instruments employing only one or two apertures, with dramatically increased intensity (a threefold increase observed in the test setup) and improved low-angle resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toughening elastomers using mussel-inspired iron-catechol complexes
Filippidi, E., Cristiani, T. R., Eisenbach, C. D., Waite, J. H., Israelachvili, J. N., Ahn, B. K., & Valentine, M. T. (2017) · Science · doi:10.1126/science.aao0350 · Cited by 757
Blanchet, C. E., Spilotros, A., Schwemmer, F., Graewert, M. A., Kikhney, A., Jeffries, C. M., Franke, D., Mark, D., Zengerle, R., Cipriani, F., et al. (2015) · Journal of Applied Crystallography · doi:10.1107/s160057671500254x · Cited by 589
A SAXS/WAXS/GISAXS Beamline with Multilayer Monochromator
Hexemer, A., Bras, W., Glossinger, J., Schaible, E., Gann, E., Kirian, R., MacDowell, A., Church, M., Rude, B., & Padmore, H. (2010) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/247/1/012007 · Cited by 540
A low-background-intensity focusing small-angle X-ray scattering undulator beamline
Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013) · Journal of Applied Crystallography · doi:10.1107/s002188981302774x · Cited by 530
Coherent Nanotwins and Dynamic Disorder in Cesium Lead Halide Perovskite Nanocrystals
Bertolotti, F., Protesescu, L., Kovalenko, M. V., Yakunin, S., Cervellino, A., Billinge, S. J. L., Terban, M. W., Pedersen, J. S., Masciocchi, N., & Guagliardi, A. (2017) · ACS Nano · doi:10.1021/acsnano.7b00017 · Cited by 302
Classen, S., Hura, G. L., Holton, J. M., Rambo, R. P., Rodic, I., McGuire, P. J., Dyer, K., Hammel, M., Meigs, G., Frankel, K. A., et al. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889812048698 · Cited by 251
“Our design was inspired by similar scatterless slits developed for SAXS experiments that use silicon or germanium crystals for the slit edges (Li et al., 2008).”
MethodA multipurpose instrument for time-resolved ultra-small-angle and coherent X-ray scattering
Narayanan, T., Sztucki, M., Van Vaerenbergh, P., Léonardon, J., Gorini, J., Claustre, L., Sever, F., Morse, J., & Boesecke, P. (2018) · Journal of Applied Crystallography · doi:10.1107/s1600576718012748 · Cited by 222
“The last guard slits are scatterless slits (Li et al., 2008) with hybrid metal/silicon crystal blades (Xenocs SA).”
BackgroundFehér, B., Zhu, K., Nyström, B., Varga, I., & Pedersen, J. S. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b01896 · Cited by 35
Structural and regulatory insights into the glideosome-associated connector from Toxoplasma gondii
Kumar, A., Vadas, O., Dos Santos Pacheco, N., Zhang, X., Chao, K., Darvill, N., Rasmussen, H. Ø., Xu, Y., Lin, G. M.-H., Stylianou, F. A., et al. (2023) · eLife · doi:10.7554/elife.86049 · Cited by 15
Metadata
- Authors
- Li, Y., Beck, R., Huang, T., Choi, M. C., & Divinagracia, M.
- Venue
- Journal of Applied Crystallography
- Published
- 2008-11-11
- Volume
- 41
- Issue
- 6
- Pages
- 1134-1139
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2038938940
- Cited by
- 158
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.