A beginner's guide to radiation damage
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Many advances in the understanding of radiation damage to protein crystals, particularly at cryogenic temperatures, have been made in recent years, but with this comes an expanding literature, and, to the new breed of protein crystallographer who is not really interested in X-ray physics or radiation chemistry but just wants to solve a biologically relevant structure, the technical nature and breadth of this literature can be daunting. The purpose of this paper is to serve as a rough guide to radiation damage issues, and to provide references to the more exacting and detailed work. No attempt has been made to report precise numbers (a factor of two is considered satisfactory), and, since there are aspects of radiation damage that are demonstrably unpredictable, the `worst case scenario' as well as the `average crystal' are discussed in terms of the practicalities of data collection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berman, H. M. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.235 · Cited by 40,196
Solvent content of protein crystals
Matthews, B. W. (1968) · Journal of Molecular Biology · doi:10.1016/0022-2836(68)90205-2 · Cited by 7,961
Scaling and assessment of data quality
Evans, P. (2006) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444905036693 · Cited by 4,374
Atomic structures of amyloid cross-β spines reveal varied steric zippers
Sawaya, M. R., Sambashivan, S., Nelson, R., Ivanova, M. I., Sievers, S. A., Apostol, M. I., Thompson, M. J., Balbirnie, M., Wiltzius, J. J. W., McFarlane, H. T., et al. (2007) · Nature · doi:10.1038/nature05695 · Cited by 2,271
Structure of the cross-β spine of amyloid-like fibrils
Nelson, R., Sawaya, M. R., Balbirnie, M., Madsen, A. Ø., Riekel, C., Grothe, R., & Eisenberg, D. (2005) · Nature · doi:10.1038/nature03680 · Cited by 2,202
The optical principles of the diffraction of x-rays.
James, R. W. (1954) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,126
Photon mass attenuation and energy-absorption coefficients
Hubbell, J. H. (1982) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(82)90248-4 · Cited by 1,459
Structures of the Bacterial Ribosome at 3.5 Å Resolution
Schuwirth, B. S., Borovinskaya, M. A., Hau, C. W., Zhang, W., Vila-Sanjurjo, A., Holton, J. M., & Cate, J. H. D. (2005) · Science · doi:10.1126/science.1117230 · Cited by 1,418
Self-citationStructure of Myoglobin: A Three-Dimensional Fourier Synthesis at 2 Å. Resolution
KENDREW, J. C., DICKERSON, R. E., STRANDBERG, B. E., HART, R. G., DAVIES, D. R., PHILLIPS, D. C., & SHORE, V. C. (1960) · Nature · doi:10.1038/185422a0 · Cited by 1,352
The Radiation Chemistry of Macromolecules
(1973) · Elsevier eBooks · doi:10.1016/c2013-0-10595-8 · Cited by 1,096
Cited by
An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Self-citationMeasurement of atom resolvability in cryo-EM maps with Q-scores
Pintilie, G., Zhang, K., Su, Z., Li, S., Schmid, M. F., & Chiu, W. (2020) · Nature Methods · doi:10.1038/s41592-020-0731-1 · Cited by 400
Radiation damage in macromolecular crystallography: what is it and why should we care?
Garman, E. F. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910008656 · Cited by 366
Self-terminating diffraction gates femtosecond X-ray nanocrystallography measurements
Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2011.297 · Cited by 344
Room-temperature macromolecular serial crystallography using synchrotron radiation
Stellato, F., Oberthür, D., Liang, M., Bean, R., Gati, C., Yefanov, O., Barty, A., Burkhardt, A., Fischer, P., Galli, L., et al. (2014) · IUCrJ · doi:10.1107/s2052252514010070 · Cited by 256
Classen, S., Hura, G. L., Holton, J. M., Rambo, R. P., Rodic, I., McGuire, P. J., Dyer, K., Hammel, M., Meigs, G., Frankel, K. A., et al. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889812048698 · Cited by 251
“They will still reach the Owen et al. (2006) damage limit (30 MGy) in about 30 min at the SIBYLS beamline (Holton, 2009; Holton & Frankel, 2010).”
BackgroundSelf-citationDiffraction before destruction
Chapman, H. N., Caleman, C., & Timneanu, N. (2014) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2013.0313 · Cited by 241
“Cryogenic cooling of the sample reduces some of the reactions that occur subsequently to photoabsorption allowing for about a 30–50 times increase in exposure [2–4].”
BackgroundRADDOSE-3D: time- and space-resolved modelling of dose in macromolecular crystallography
Zeldin, O. B., Gerstel, M., & Garman, E. F. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813011461 · Cited by 239
“Radiation damage is one of the most common causes for the failure of X-ray macromolecular crystallography (MX) experiments (Holton, 2009; Garman, 2010).”
BackgroundJuanhuix, J., Gil-Ortiz, F., Cuní, G., Colldelram, C., Nicolás, J., Lidón, J., Boter, E., Ruget, C., Ferrer, S., & Benach, J. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s160057751400825x · Cited by 203
“…of the beam to the size of the crystal improves the ratio between the diffracted intensities and the background scattering, which allows us to better estimate the radiation damage, provided that the beam illuminates uniformly the crystal (Bourenkov & Popov, 2006; Holton, 2009; Garman, 2010).”
BackgroundMegahertz serial crystallography
Wiedorn, M. O., Oberthür, D., Bean, R., Schubert, R., Werner, N., Abbey, B., Aepfelbacher, M., Adriano, L., Allahgholi, A., Al-Qudami, N., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06156-7 · Cited by 201
Molecular Imaging Using X-Ray Free-Electron Lasers
Barty, A., Küpper, J., & Chapman, H. N. (2013) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032511-143708 · Cited by 194
Keedy, D. A., Kenner, L. R., Warkentin, M., Woldeyes, R. A., Hopkins, J. B., Thompson, M. C., Brewster, A. S., Van Benschoten, A. H., Baxter, E. L., Uervirojnangkoorn, M., et al. (2015) · eLife · doi:10.7554/elife.07574 · Cited by 191
“61 62 However, more than 95% of crystal structures are determined at cryogenic temperatures (~100 K) to reduce 63 radiation damage by minimizing diffusion of reactive intermediates and chemical-damage-induced structural 64 relaxations (Garman, 2010; Holton, 2009; Warkentin et al., 2013).”
BackgroundSelf-citationThe minimum crystal size needed for a complete diffraction data set
Holton, J. M., & Frankel, K. A. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910007262 · Cited by 189
“Therefore, A is a small correction in typical cases and only becomes significant if strongly absorbing atoms are soaked into the crystal (see Holton, 2009) or if long- wavelength X-rays are used.”
BackgroundResultInfluentialSelf-citationAnalysis of Global and Site-Specific Radiation Damage in Cryo-EM
Hattne, J., Shi, D., Glynn, C., Zee, C.-T., Gallagher-Jones, M., Martynowycz, M. W., Rodriguez, J. A., & Gonen, T. (2018) · Structure · doi:10.1016/j.str.2018.03.021 · Cited by 179
Cobamide-mediated enzymatic reductive dehalogenation via long-range electron transfer
Kunze, C., Bommer, M., Hagen, W. R., Uksa, M., Dobbek, H., Schubert, T., & Diekert, G. (2017) · Nature Communications · doi:10.1038/ncomms15858 · Cited by 104
Metadata
- Authors
- Holton, J. M.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2009-02-25
- Volume
- 16
- Issue
- 2
- Pages
- 133-142
- ISSN
- 0909-0495 (ISSN-L)
- OpenAlex
- W2116305502
- Cited by
- 260
- References
- 46
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.