A customizable software for fast reduction and analysis of large X-ray scattering data sets: applications of the new DPDAK package to small-angle X-ray scattering and grazing-incidence small-angle X-ray scattering
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
X-ray scattering experiments at synchrotron sources are characterized by large and constantly increasing amounts of data. The great number of files generated during a synchrotron experiment is often a limiting factor in the analysis of the data, since appropriate software is rarely available to perform fast and tailored data processing. Furthermore, it is often necessary to perform online data reduction and analysis during the experiment in order to interactively optimize experimental design. This article presents an open-source software package developed to process large amounts of data from synchrotron scattering experiments. These data reduction processes involve calibration and correction of raw data, one- or two-dimensional integration, as well as fitting and further analysis of the data, including the extraction of certain parameters. The software,DPDAK(directly programmable data analysis kit), is based on a plug-in structure and allows individual extension in accordance with the requirements of the user. The article demonstrates the use of DPDAK for on- and offline analysis of scanning small-angle X-ray scattering (SAXS) data on biological samples and microfluidic systems, as well as for a comprehensive analysis of grazing-incidence SAXS data. In addition to a comparison with existing software packages, the structure of DPDAK and the possibilities and limitations are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996) · High Pressure Research · doi:10.1080/08957959608201408 · Cited by 4,674
(2016) · Encyclopedia of Nanotechnology · doi:10.1007/978-94-017-9780-1_101037 · Cited by 3,780
Die Röntgenkleinwinkelstreuung von dichtgepackten kolloiden Systemen: I. Teil
Porod, G. (1951) · Kolloid-Zeitschrift · doi:10.1007/bf01512792 · Cited by 1,711
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Anomalous Surface Reflection of X Rays
Yoneda, Y. (1963) · Physical Review · doi:10.1103/physrev.131.2010 · Cited by 675
Hydrodynamic alignment and assembly of nanofibrils resulting in strong cellulose filaments
Håkansson, K. M. O., Fall, A. B., Lundell, F., Yu, S., Krywka, C., Roth, S. V., Santoro, G., Kvick, M., Prahl Wittberg, L., Wågberg, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5018 · Cited by 523
Self-citationMüller-Buschbaum, P. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1869-2 · Cited by 357
Self-citationBuffet, A., Rothkirch, A., Döhrmann, R., Körstgens, V., Abul Kashem, M. M., Perlich, J., Herzog, G., Schwartzkopf, M., Gehrke, R., Müller-Buschbaum, P., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512016895 · Cited by 351
Self-citationPyFAI, a versatile library for azimuthal regrouping
Kieffer, J., & Karkoulis, D. (2013) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/425/20/202012 · Cited by 301
Small Angle X-Ray and Neutron Scattering from Solutions of Biological Macromolecules
Svergun, D. I., Koch, M. H. J., Timmins, P. A., & May, R. P. (2013) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780199639533.001.0001 · Cited by 286
Cited by
DIOPTAS: a program for reduction of two-dimensional X-ray diffraction data and data exploration
Prescher, C., & Prakapenka, V. B. (2015) · High Pressure Research · doi:10.1080/08957959.2015.1059835 · Cited by 1,981
State of the Art and Prospects for Halide Perovskite Nanocrystals
Dey, A., Ye, J., De, A., Debroye, E., Ha, S. K., Bladt, E., Kshirsagar, A. S., Wang, Z., Yin, J., Wang, Y., et al. (2021) · ACS Nano · doi:10.1021/acsnano.0c08903 · Cited by 1,478
Self-citationThe fast azimuthal integration Python library:pyFAI
Ashiotis, G., Deschildre, A., Nawaz, Z., Wright, J. P., Karkoulis, D., Picca, F. E., & Kieffer, J. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576715004306 · Cited by 927
Hopkins, J. B., Gillilan, R. E., & Skou, S. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717011438 · Cited by 646
Li, Y., Fu, Q., Yu, S., Yan, M., & Berglund, L. (2016) · Biomacromolecules · doi:10.1021/acs.biomac.6b00145 · Cited by 570
Processing two-dimensional X-ray diffraction and small-angle scattering data in DAWN 2
Filik, J., Ashton, A. W., Chang, P. C. Y., Chater, P. A., Day, S. J., Drakopoulos, M., Gerring, M. W., Hart, M. L., Magdysyuk, O. V., Michalik, S., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717004708 · Cited by 530
Li, N., Perea, J. D., Kassar, T., Richter, M., Heumueller, T., Matt, G. J., Hou, Y., Güldal, N. S., Chen, H., Chen, S., et al. (2017) · Nature Communications · doi:10.1038/ncomms14541 · Cited by 383
High-efficiency and thermally stable FACsPbI3 perovskite photovoltaics
Li, S., Jiang, Y., Xu, J., Wang, D., Ding, Z., Zhu, T., Chen, B., Yang, Y., Wei, M., Guo, R., et al. (2024) · Nature · doi:10.1038/s41586-024-08103-7 · Cited by 361
Nano-optical designs for high-efficiency monolithic perovskite–silicon tandem solar cells
Tockhorn, P., Sutter, J., Cruz, A., Wagner, P., Jäger, K., Yoo, D., Lang, F., Grischek, M., Li, B., Li, J., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01228-8 · Cited by 345
Advanced grazing-incidence techniques for modern soft-matter materials analysis
Hexemer, A., & Müller-Buschbaum, P. (2015) · IUCrJ · doi:10.1107/s2052252514024178 · Cited by 263
Self-citationSmall-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Degradation mechanisms of perovskite solar cells under vacuum and one atmosphere of nitrogen
Guo, R., Han, D., Chen, W., Dai, L., Ji, K., Xiong, Q., Li, S., Reb, L. K., Scheel, M. A., Pratap, S., et al. (2021) · Nature Energy · doi:10.1038/s41560-021-00912-8 · Cited by 219
Self-citationLi, Y., Yu, S., Chen, P., Rojas, R., Hajian, A., & Berglund, L. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.03.010 · Cited by 184
In situ differentiation of iridophore crystallotypes underlies zebrafish stripe patterning
Gur, D., Bain, E. J., Johnson, K. R., Aman, A. J., Pasolli, H. A., Flynn, J. D., Allen, M. C., Deheyn, D. D., Lee, J. C., Lippincott-Schwartz, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-20088-1 · Cited by 69
Metadata
- Authors
- Benecke, G., Wagermaier, W., Li, C., Schwartzkopf, M., Flucke, G., Hoerth, R., Zizak, I., Burghammer, M., Metwalli, E., Müller-Buschbaum, P., Trebbin, M., Förster, S., Paris, O., Roth, S. V., & Fratzl, P.
- Venue
- Journal of Applied Crystallography
- Published
- 2014-09-30
- Volume
- 47
- Issue
- 5
- Pages
- 1797-1803
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W2125485249
- Cited by
- 333
- References
- 24
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.