XFELs for structure and dynamics in biology
Open accessThe DOI matches its Crossref record; 143 of the 143 references it cites were found in a registry or an index.
Abstract
The development and application of the free-electron X-ray laser (XFEL) to structure and dynamics in biology since its inception in 2009 are reviewed. The research opportunities which result from the ability to outrun most radiation-damage effects are outlined, and some grand challenges are suggested. By avoiding the need to cool samples to minimize damage, the XFEL has permitted atomic resolution imaging of molecular processes on the 100 fs timescale under near-physiological conditions and in the correct thermal bath in which molecular machines operate. Radiation damage, comparisons of XFEL and synchrotron work, single-particle diffraction, fast solution scattering, pump–probe studies on photosensitive proteins, mix-and-inject experiments, caged molecules, pH jump and other reaction-initiation methods, and the study of molecular machines are all discussed. Sample-delivery methods and data-analysis algorithms for the various modes, from serial femtosecond crystallography to fast solution scattering, fluctuation X-ray scattering, mixing jet experiments and single-particle diffraction, are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Overview of the CCP 4 suite and current developments
Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., et al. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910045749 · Cited by 12,353 · cited 1×
“Indexing has mostly been achieved using standard crystallography software (for example MOSFLM; Winn et al., 2011), allowing the data from many microcrystals to be merged into a three-dimensional diffraction volume.”
MethodPhase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596 · cited 1×
“…per shot, the methods of coherent diffractive imaging (CDI) have been adapted for XFEL data, including the hybrid input–output (HIO) algorithm (Fienup, 1982) and its variants [see Marchesini (2007) and Spence (2017c) for reviews and Millane & Lo (2013) for a review of related iterative…”
MethodDynamic personalities of proteins
Henzler-Wildman, K., & Kern, D. (2007) · Nature · doi:10.1038/nature06522 · Cited by 2,545 · cited 1×
“It has been suggested in one approach (Henzler-Wildman & Kern, 2007) that the conformational substates sampled by a protein and the pathways between them are not random, but rather a result of the evolutionary selection of states that are needed for protein function, and hence are ‘pre-formed’.”
BackgroundFemtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086 · cited 16×
“Diffraction patterns are read out at 120 Hz at the LCLS.”
MethodInfluentialSelf-citationPotential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×
“This idea that one could ‘out-run’ radiation damage was then further explored by Solem (1986) and, in detail, in response to the promise of the XFEL with its highintensity femtosecond pulses, in molecular-dynamics simulations by Neutze et al. (2000).”
BackgroundA compact X-ray free-electron laser emitting in the sub-ångström region
Ishikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.141 · Cited by 1,819 · cited 1×
“A second started at the Japanese SACLA laboratory in 2012 (Ishikawa et al., 2012).”
BackgroundThe Catalytic Pathway of Cytochrome P450cam at Atomic Resolution
Schlichting, I., Berendzen, J., Chu, K., Stock, A. M., Maves, S. A., Benson, D. E., Sweet, R. M., Ringe, D., Petsko, G. A., & Sligar, S. G. (2000) · Science · doi:10.1126/science.287.5458.1615 · Cited by 1,331 · cited 1×
“Reactions can be triggered by the photoelectrons generated by the X-ray beam itself, as in the cases of cytochrome P450 (Schlichting et al., 2000) and horseradish peroxidase (Berglund et al., 2002).”
BackgroundHenderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194 · cited 1×
“A fuller analysis (Henderson, 1995) used this ratio multiplied by the average amount of energy deposited in the sample by inelastic scattering as a figure of merit to compare damage and resolution for electrons and X-ray diffraction (XRD).”
MethodFemtosecond diffractive imaging with a soft-X-ray free-electron laser
Chapman, H. N., Barty, A., Bogan, M. J., Boutet, S., Frank, M., Hau-Riege, S. P., Marchesini, S., Woods, B. W., Bajt, S., Benner, W. H., et al. (2006) · Nature Physics · doi:10.1038/nphys461 · Cited by 1,026 · cited 1×
“The first experimental evidence for this ‘diffractthen-destroy’ mechanism came at lower resolution using the VUV laser Flash at DESY in 2006 (Chapman et al., 2006), suggesting the possibility of high-resolution, almost damagefree ‘movies’ (Spence, 2008).”
Background
Cited by
Electron diffraction determines molecular absolute configuration in a pharmaceutical nanocrystal
Brázda, P., Palatinus, L., & Babor, M. (2019) · Science · doi:10.1126/science.aaw2560 · Cited by 181
X-Ray Free-Electron Lasers for the Structure and Dynamics of Macromolecules
Chapman, H. N. (2019) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-013118-110744 · Cited by 174
“Since the relative energies of two conformations depend on the exponent of the ratio of their populations, Spence has argued that high-throughput single-particle FEL experiments may acquire many millions of measurements, enough to map energy differences exceeding that of the energy available from ATP per molecule (149…”
BackgroundThe hit-and-return system enables efficient time-resolved serial synchrotron crystallography
Schulz, E. C., Mehrabi, P., Müller-Werkmeister, H. M., Tellkamp, F., Jha, A., Stuart, W., Persch, E., De Gasparo, R., Diederich, F., Pai, E. F., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0180-2 · Cited by 111
Metadata
- Authors
- Spence, J. C. H.
- Venue
- IUCrJ
- Published
- 2017-05-10
- Volume
- 4
- Issue
- 4
- Pages
- 322-339
- ISSN
- 2052-2525 (ISSN-L)
- OpenAlex
- W2613580110
- Cited by
- 177
- References
- 143
- FWCI
- 21.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.