XFELs for structure and dynamics in biology
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The development and application of the free-electron X-ray laser (XFEL) to structure and dynamics in biology since its inception in 2009 are reviewed. The research opportunities which result from the ability to outrun most radiation-damage effects are outlined, and some grand challenges are suggested. By avoiding the need to cool samples to minimize damage, the XFEL has permitted atomic resolution imaging of molecular processes on the 100 fs timescale under near-physiological conditions and in the correct thermal bath in which molecular machines operate. Radiation damage, comparisons of XFEL and synchrotron work, single-particle diffraction, fast solution scattering, pump–probe studies on photosensitive proteins, mix-and-inject experiments, caged molecules, pH jump and other reaction-initiation methods, and the study of molecular machines are all discussed. Sample-delivery methods and data-analysis algorithms for the various modes, from serial femtosecond crystallography to fast solution scattering, fluctuation X-ray scattering, mixing jet experiments and single-particle diffraction, are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of the CCP 4 suite and current developments
Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., et al. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910045749 · Cited by 12,353 · cited 1×
“Indexing has mostly been achieved using standard crystallography software (for example MOSFLM; Winn et al., 2011), allowing the data from many microcrystals to be merged into a three-dimensional diffraction volume.”
MethodDynamic personalities of proteins
Henzler-Wildman, K., & Kern, D. (2007) · Nature · doi:10.1038/nature06522 · Cited by 2,545
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×
“This idea that one could ‘out-run’ radiation damage was then further explored by Solem (1986) and, in detail, in response to the promise of the XFEL with its highintensity femtosecond pulses, in molecular-dynamics simulations by Neutze et al. (2000).”
BackgroundSingle mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Self-citationThe First Step in Vision: Femtosecond Isomerization of Rhodopsin
Schoenlein, R. W., Peteanu, L. A., Mathies, R. A., & Shank, C. V. (1991) · Science · doi:10.1126/science.1925597 · Cited by 892
Protein states and proteinquakes.
Ansari, A., Berendzen, J., Bowne, S. F., Frauenfelder, H., Iben, I. E., Sauke, T. B., Shyamsunder, E., & Young, R. D. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.15.5000 · Cited by 828 · cited 1×
“The epicenter of the ‘quake’ (Ansari et al., 1985) was seen to occur at the chlorophyll cofactors.”
BackgroundFenimore, P. W., Frauenfelder, H., McMahon, B. H., & Young, R. D. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405573101 · Cited by 524
Indications of radiation damage in ferredoxin microcrystals using high-intensity X-FEL beams
Nass, K., Foucar, L., Barends, T. R. M., Hartmann, E., Botha, S., Shoeman, R. L., Doak, R. B., Alonso-Mori, R., Aquila, A., Bajt, S., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515002349 · Cited by 131 · cited 1×
“Recently, site-specific damage effects have been imaged in density maps around Fe metal clusters in ferredoxin using XFEL data (Nass et al., 2015) and compared with synchrotron results.”
ResultMultiwavelength Anomalous Diffraction at High X-Ray Intensity
Son, S.-K., Chapman, H. N., & Santra, R. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.218102 · Cited by 120 · cited 1×
“By sorting the data according to pulse intensity, an analysis similar to SAD or isomorphous replacement may then be applied (Son et al., 2011).”
MethodImaging biological specimens with high-intensity soft x rays
Solem, J. C. (1986) · Journal of the Optical Society of America B · doi:10.1364/josab.3.001551 · Cited by 92 · cited 1×
“This idea that one could ‘out-run’ radiation damage was then further explored by Solem (1986) and, in detail, in response to the promise of the XFEL with its highintensity femtosecond pulses, in molecular-dynamics simulations by Neutze et al. (2000).”
Background
Cited by
Electron diffraction determines molecular absolute configuration in a pharmaceutical nanocrystal
Brázda, P., Palatinus, L., & Babor, M. (2019) · Science · doi:10.1126/science.aaw2560 · Cited by 181
The hit-and-return system enables efficient time-resolved serial synchrotron crystallography
Schulz, E. C., Mehrabi, P., Müller-Werkmeister, H. M., Tellkamp, F., Jha, A., Stuart, W., Persch, E., De Gasparo, R., Diederich, F., Pai, E. F., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0180-2 · Cited by 111
Metadata
- Authors
- Spence, J. C. H.
- Venue
- IUCrJ
- Published
- 2017-05-10
- Volume
- 4
- Issue
- 4
- Pages
- 322-339
- ISSN
- 2052-2525 (ISSN-L)
- OpenAlex
- W2613580110
- Cited by
- 177
- References
- 10
- FWCI
- 21.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.