The electromyogram (EMG) as a control signal for functional neuromuscular stimulation. I. Autoregressive modeling as a means of EMG signature discrimination
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The successful application of functional neuromuscular stimulation to the muscles of paraplegics depends to a large extent on the adequate provision of a means by which the subject can exercise control over the resulting movement. The use of above-lesion electromyographic signals as a solution to the control problem is considered. A number of criteria for such a control system are defined. The general concepts underlying time-series analysis are described and the suitability of this method as a means of processing electromyographic signals is investigated. The electromyogram, which exhibits weak stationarity over short time intervals, is represented by a fourth-order autoregressive model. A sequential least-squares algorithm is used to determine the model parameters, which are then used to achieve signature discrimination.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126
Cited by
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
“Faster is clearly better, but what is good enough? Farrell et al found that participants did not appreciate a time delay of less than 100 ms,(22) and others have advocated that a delay of up to 300 to 400 ms is acceptable.(20,21,23) Thus the motion selection times of TMR patients for arm function are quite good ( 220…”
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Hefftner, G., Zucchini, W., & Jaros, G. G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1988-04
- Volume
- 35
- Issue
- 4
- Pages
- 230-237
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2139045199
- Cited by
- 118
- References
- 3
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.