The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Time-variant power spectrum analysis for the detection of transient episodes in HRV signal
Abstract
A time-variant algorithm of autoregressive (AR) identification is introduced and applied to the heart rate variability (HRV) signal. The power spectrum is calculated from the AR coefficients derived from each single RR interval considered. Time-variant AR coefficients are determined through adaptive parametric identification with a forgetting factor which obtains weighed values on a running temporal window of 50 preceding measurements. Power spectrum density (PSD) is hence obtained at each cardiac cycle, making it possible to follow the dynamics of the spectral parameters on a beat-by-beat basis. These parameters are mainly the LF (low frequency) and the HF (high frequency) powers, and their ratio LF/HF. These together account for the balanced sympatho-vagal control mechanism affecting the heart rate. This method is applied to subjects suffering from transient ischemic attacks. The time variant spectral parameters suggest an early activation of LF component in the HRV power spectrum. It precedes by approximately 1.5-2 min the tachycardia and the ST displacement, generally indicative of the onset of an ischemic episode. The results suggest an arousal of sympathetic system before the acute attack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Malik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Heart Rate Turbulence: Standards of Measurement, Physiological Interpretation, and Clinical Use
Bauer, A., Malik, M., Schmidt, G., Barthel, P., Bonnemeier, H., Cygankiewicz, I., Guzik, P., Lombardi, F., Müller, A., Oto, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.041 · Cited by 462
Barbieri, R., Matten, E. C., Alabi, A. A., & Brown, E. N. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00482.2003 · Cited by 307
Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1827 · Cited by 85
“In a few further cases, a separate device was used to record the ECG at one or more SFEx (Bianchi et al 1993, Pinna et al 1994, Chellakumar et al 2005), introducing a possible confound (i.e. if device-induced measurement artifacts were present).”
MethodResultProcessing of signals recorded through smart devices: Sleep-quality assessment
Bianchi, A. M., Mendez, M. O., & Cerutti, S. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2049025 · Cited by 61
Effects of Reboxetine on Sleep and Nocturnal Cardiac Autonomic Activity in Patients with Dysthymia
Ferini-Strambi, L., Manconi, M., Castronovo, V., Riva, L., & Bianchi, A. (2004) · Journal of Psychopharmacology · doi:10.1177/026988110401800313 · Cited by 17
Self-citation
Metadata
- Authors
- Bianchi, A. M., Mainardi, L., Petrucci, E., Signorini, M. G., Mainardi, M., & Cerutti, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993
- Volume
- 40
- Issue
- 2
- Pages
- 136-144
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2113166194
- Cited by
- 222
- References
- 3
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.