The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A linear discretization of the volume conductor boundary integral equation using analytically integrated elements (electrophysiology application)
Abstract
A method is presented to compute the potential distribution on the surface of a homogeneous isolated conductor of arbitrary shape. The method is based on an approximation of a boundary integral equation as a set linear algebraic equations. The potential is described as a piecewise linear or quadratic function. The matrix elements of the discretized equation are expressed as analytical formulas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Research works printed but not linked: 16
- 10.1109/TBME.1983.325207 · DOI · Paper page
- 10.1137/0705027 · DOI
- kuwahara, 1987, An effective analysis for three dimensional boundary element method using analytically integrated higher order elements, Trans IEE Japan, 107a, 275
- kuwahara, 1987, A formula of boundary integral for potential problem and its consideration, Proc First Japan-China Symp Boundary Element Methods Theory Apply, 47
- 10.1016/0307-904X(81)90047-0 · doi:10.1016/0307-904x(81)90047-0
- 10.1016/0955-7997(89)90006-4 · doi:10.1016/0955-7997(89)90006-4
- 10.1016/0955-7997(89)90001-5 · doi:10.1016/0955-7997(89)90001-5
- stroud, 1971, Approximate calculation of multiple integrals, 314
- 10.1016/S0006-3495(67)86599-8 · DOI · Paper page
- 10.1109/10.40805 · DOI · Paper page
- 10.1007/978-3-642-48860-3 · DOI · Paper page
- 10.1109/TBME.1977.326201 · DOI · Paper page
- meijs, 1985, Computation of MEGs and EEGs using a realistically shaped multi-compartment model of the head, Med Biol Eng Comp, 23, 36
- nyssen, 1986, Potentiaalkaarten in de elektrokardiologie Een zoektocht naar technieken voor de verbetering van hun klinische toepassing
- meijs, 1988, The influence of head geometries on electro- and magnetoencephalograms
- meijs, 1985, Computation of MEG's and EEG's using a realistically shaped multi compartment model of the head, Med Biol Eng Comput, 23, 36
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
OpenMEEG: opensource software for quasistatic bioelectromagnetics
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-45 · Cited by 1,154
Nolte, G. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/22/002 · Cited by 1,022
A standardized boundary element method volume conductor model
Fuchs, M., Kastner, J., Wagner, M., Hawes, S., & Ebersole, J. S. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00030-5 · Cited by 999
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Metadata
- Authors
- de Munck, J. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992
- Volume
- 39
- Issue
- 9
- Pages
- 986-990
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2147807765
- Cited by
- 193
- References
- 1
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.