An electrode, designed to be implanted without a surgical incision, was developed for skeletal muscle stimulation. Stainless steel, Teflon-insulated wire was wound into a helical lead around a polypropylene core and then rewound into a double helix configuration for stress relief during muscle contractions. The electrode tip was augmented with stainless steel barbs to increase anchoring strength. Electrodes were implanted with the help of specially modified hypodermic needles, sheaths, and passing tubes. 775 electrodes were implanted in a five year period in 22 subjects; accumulated implant time was 1,080 electrode years. 453 electrodes (65%) continue to produce strong, stable, muscle contractions. Electrode longevity varied with the location of implant. Electrodes were removed because of (1) inability to locate and properly place the electrode in a suitable site for stimulation during surgery (28.4%), (2) unwanted changes in muscle response to stimulation (91, 12%; one-third occurring during the first six weeks post implant), (3) increase in electrode impedance (74, 10%; assumed breakage, mostly occurring during the first year after implant), (4) intolerable pain during stimulation (8, 1%), and (5) infection (4, 0.5%). 67 (8%) electrodes were removed by accident or when the subjects left the program. This double helix electrode design has proven practical for achieving chronic stimulation of selected muscles in hemiplegic, paraplegic, stroke and brain-injured subjects with minimally invasive surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intramuscular electrical stimulation: Tissue damage
Mortimer, J. T., Kaufman, D., & Roessmann, U. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02364479 · Cited by 123
Imbalanced biphasic electrical stimulation: Muscle tissue damage
Scheiner, A., Mortimer, J. T., & Roessmann, U. (1990) · Annals of Biomedical Engineering · doi:10.1007/bf02364157 · Cited by 117
Self-citation
Cited by
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Self-citationSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
“Epimysial and intramuscular electrodes have restored short-duration standing and stepping function to select individuals with paraplegia (Scheiner et al 1994, Triolo et al 1995, 1996, 2001, Daly et al 2001, Guiraud et al 2006).”
BackgroundTriolo, R. J., Bieri, C., Uhlir, J., Kobetic, R., Scheiner, A., & Marsolais, E. B. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90133-1 · Cited by 102
Self-citationFunctional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Self-citation
Metadata
- Authors
- Scheiner, A., Polando, G., & Marsolais, E. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1994-05
- Volume
- 41
- Issue
- 5
- Pages
- 425-431
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2123335784
- Cited by
- 67
- References
- 2
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.