Design and clinical application of a double helix electrode for functional electrical stimulation

Scheiner, A., Polando, G., Marsolais, E.B. · 1994 · IEEE Transactions on Biomedical Engineering
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

An electrode, designed to be implanted without a surgical incision, was developed for skeletal muscle stimulation. Stainless steel, Teflon-insulated wire was wound into a helical lead around a polypropylene core and then rewound into a double helix configuration for stress relief during muscle contractions. The electrode tip was augmented with stainless steel barbs to increase anchoring strength. Electrodes were implanted with the help of specially modified hypodermic needles, sheaths, and passing tubes. 775 electrodes were implanted in a five year period in 22 subjects; accumulated implant time was 1,080 electrode years. 453 electrodes (65%) continue to produce strong, stable, muscle contractions. Electrode longevity varied with the location of implant. Electrodes were removed because of (1) inability to locate and properly place the electrode in a suitable site for stimulation during surgery (28.4%), (2) unwanted changes in muscle response to stimulation (91, 12%; one-third occurring during the first six weeks post implant), (3) increase in electrode impedance (74, 10%; assumed breakage, mostly occurring during the first year after implant), (4) intolerable pain during stimulation (8, 1%), and (5) infection (4, 0.5%). 67 (8%) electrodes were removed by accident or when the subjects left the program. This double helix electrode design has proven practical for achieving chronic stimulation of selected muscles in hemiplegic, paraplegic, stroke and brain-injured subjects with minimally invasive surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.293216

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Scheiner, A., Polando, G., & Marsolais, E. B.
Venue
IEEE Transactions on Biomedical Engineering
Published
1994-05
Volume
41
Issue
5
Pages
425-431
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2123335784
Cited by
67
References
2
FWCI
1.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.