Synthesis of hand grasp using functional neuromuscular stimulation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A functional neuromuscular stimulation system has been developed to provide grasp-release function in quadriplegic individuals. A single command input from the subject controls the stimulus levels to a number of electrodes, thus simultaneously activating several muscles. A method for synthesizing the command input to stimulus output relationship has been developed. The first step involves electrode profiling, which is a method for characterizing the output of an individual electrode/muscle combination. The electrodes are then grouped according to function and a set of rule based procedures is used to synthesize the basic grasp parameters. Results are presented demonstrating the output from lateral and palmar grasps developed by this method. The method has successfully resulted in grasping patterns that can be utilized functionally. Limitations of the method and future improvements are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216
Self-citation
Cited by
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Self-citationPeckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Self-citationAn Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationAn Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, K. L., Hoyen, H. A., Bryden, A. M., Hart, R. L., Keith, M. W., & Peckham, P. H. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2008.01.007 · Cited by 189
Self-citationImplanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
Self-citation
Metadata
- Authors
- Kilgore, K. L., Peckham, P. H., Thrope, G. B., Keith, M. W., & Gallaher-Stone, K. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 761-770
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1974516244
- Cited by
- 152
- References
- 1
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.