Cited by 319Spinal Cord Injury ResearchStroke Rehabilitation and RecoveryNeuroscience and Neural Engineering

Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: A multicenter study

Peckham, P.Hunter, Keith, Michael W., Kilgore, Kevin L., Grill, Julie H., Wuolle, Kathy S., Thrope, Geoffrey B., Gorman, Peter, Hobby, John +4 more·2001·Archives of Physical Medicine and Rehabilitation

Abstract

Objective To evaluate an implanted neuroprosthesis that allows tetraplegic users to control grasp and release in 1 hand.Design Multicenter cohort trial with at least 3 years of follow-up. Function for each participant was compared before and after implantation, and with and without the neuroprosthesis activated.Setting Tertiary spinal cord injury (SCI) care centers, 8 in the United States, 1 in the United Kingdom, and 1 in Australia.Participants Fifty-one tetraplegic adults with C5 or C6 SCIs.Intervention An implanted neuroprosthetic system, in which electric stimulation of the grasping muscles of 1 arm are controlled by using contralateral shoulder movements, and concurrent tendon transfer surgery. Assessed participants' ability to grasp, move, and release standardized objects; degree of assistance required to perform activities of daily living (ADLs), device usage; and user satisfaction.Main outcome measures Pinch force; grasp and release tests; ADL abilities test and ADL assessment test; and user satisfaction survey.Results Pinch force was significantly greater with the neuroprosthesis in all available 50 participants, and grasp-release abilities were improved in 49. All tested participants (49/49) were more independent in performing ADLs with the neuroprosthesis than they were without it. Home use of the device for regular function and exercise was reported by over 90% of the participants, and satisfaction with the neuroprosthesis was high.Conclusions The grasping ability provided by the neuroprosthesis is substantial and lasting. The neuroprosthesis is safe, well accepted by users, and offers improved independence for a population without comparable alternatives.

Integrity signals

Registry

Crossref · 10.1053/apmr.2001.25910

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., Hentz, V. R., & Wiegner, A.
Affiliations
  • The University of Melbourne (AU)
  • United States Department of Veterans Affairs (US)
Venue
Archives of Physical Medicine and Rehabilitation
Publisher
Elsevier BV
Published
2001-10
Volume
82
Issue
10
Pages
1380-1388
ISSN
0003-9993 (ISSN-L)
OpenAlex
W2044493647
Cited by
319
References
36
Citations by year
2026: 6 · 2025: 4 · 2024: 6 · 2023: 14 · 2022: 14 · 2021: 12 · 2020: 14 · 2019: 22 · 2018: 16 · 2017: 12 · 2016: 13 · 2015: 11 · 2014: 19 · 2013: 9 · 2012: 13
FWCI
9.26
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Physical Medicine and Rehabilitation (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Center for Research Resources (M01RR000080, 5M01RR 00080)
Topics
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
tetraplegia, spinal cord injury, hand grasp, grasp and release, tendon transfer, pinch strength, activities of daily living, user satisfaction, upper limb prosthesis
MeSH terms
Adult, Electric Stimulation, Electrodes, Implanted, Female, Follow-Up Studies, Hand, Humans, Male, Prosthesis Design, Quadriplegia, Cohort Studies, Hand Strength, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›