Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Abstract
The input-output relationships for modulation of force by recruitment during intramuscular electrical stimulation were examined for cat sleus muscles and human finger and thumb muscles. Recruitment was modulated by varying either the pulsewidth or amplitude of a monophasic, rectangular, cathodal current pulse train. Force was a nonlinear function of either pulsewidth or amplitude, and the shape of the nonlinearity was the same regardless of which parameter was modulated. The charge per stimulus pulse was lowest if pulsewidth was modulated with a fixed, high amplitude stimulus. The shape of the nonlinear relationship between pulsewidth and force (recruitment characteristic) depended on stimulus amplitude, electrode location in the muscle and muscle length. In most applications the amplitude and location would be fixed, so force would be a two-dimensional nonlinear function of pulsewidth and muscle length. The results are discussed with respect to possible mechanisns of recruitment during intramuscular stimulation, and the implications of the nonlinearities on the proportional control of orthoses employing electrically stimulated muscles.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Another problem derives from the lack of selective, size-programmed activation of motor units within each muscle, thus limiting the period of use by muscle fatigue.
“Another problem derives from the lack of selective, size-programmed activation of motor units within each muscle, thus limiting the period of use by muscle fatigue”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Crago et al., 1980
Cites
PROPERTIES OF MOTOR UNITS IN A HOMOGENEOUS RED MUSCLE (SOLEUS) OF THE CAT
McPhedran, A. M., Wuerker, R. B., & Henneman, E. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.1.71 · Cited by 323 · see citing works
Crago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · see citing works
The neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Grill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103 · see citing works
Peripheral nerve stimulation for restoration of motor function
Bhadra, N., & Peckham, P. H. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00004 · Cited by 80 · see citing works
Self-citationA Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56 · see citing works
A neuroprosthesis for control of seated balance after spinal cord injury
Audu, M. L., Lombardo, L. M., Schnellenberger, J. R., Foglyano, K. M., Miller, M. E., & Triolo, R. J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-8 · Cited by 38 · see citing works
- Authors
- Crago, P. E., Peckham, P. H., & Thrope, G. B.
- Affiliations
- Case Western Reserve University (US)
- ORCID
- Crago, Patrick E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1980-12
- Volume
- BME-27
- Issue
- 12
- Pages
- 679-684
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2000185603
- Cited by
- 216
- References
- 2
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 1 · 2020: 6 · 2019: 5 · 2018: 8 · 2017: 6 · 2016: 4 · 2015: 4 · 2014: 11 · 2013: 9 · 2012: 1
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Neurology › Botulinum Toxin and Related Neurological Disorders
- Keywords
- intramuscular electrical stimulation, motor unit recruitment, input-output relationship, pulse duration, stimulus amplitude, muscle length, electrode placement, electrically stimulated muscle
- MeSH terms
- Animals, Cats, Electric Stimulation, Electrodes, Implanted, Electrophysiology, Electric Stimulation Therapy, Hand, Hindlimb, Humans, Muscle Contraction, Muscles, Neural Conduction, Recruitment, Neurophysiological, Spinal Cord Injuries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review