Electrode characterization for functional application to upper extremity FNS
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A quantitative method has been developed to characterize the isometric force vectors of electrically stimulated paralyzed muscles of the thumb. The vectorial force output as a function of the stimulus level was measured for individual electrode/muscle combinations in a number of intramuscular and epimysial electrodes implanted in paralyzed thenar muscles of cervical level spinal cord injury subejcts. Vectors are used to determine the output characteristics of each electrode/muscle combination. The characteristics studied include: the strength of the contraction, the stimulus level at which fibers from other muscles are stimulated, the recruitment gain of force, dependency of the output on the skeletal position, and the direction of force produced. These characteristics can then be used to select stimulus parameters to produce coordinated hand motion and force generation by functional neuromuscular stimulation (FNS). The range of muscle force and direction for each electrode/muscle combination showed considerable variation between subjects and between electrodes in the same subject. This variation is primarily due to differences in electrode placement within the muscle. Comparison between intramuscular and epimysial electrodes demonstrated similar characteristics in the force vector output. Preliminary results show the potential for using the force vector output to predict the cocontracted output of two muscles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216 · cited 1×
“The results obtained have shown that this is usually the case as shown by the magnitude plot in Fig. 8. This figure shows the normalized forces at extension and abduction plotted against the normalized force at the resting position (see Crag0 et al. [ 4 ] for further explanation).”
ResultSelf-citationRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
Crago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133
Self-citation
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationImplanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
“electrodes placed on or in the muscle tissue, provide an excellent combination of full recruitment and dynamic modulation range for fine manipulation [19].”
BackgroundMethodSelf-citationDurability of implanted electrodes and leads in an upper-limb neuroprosthesis
Kilgore, K. L., Peckham, P. H., Keith, M. W., Montague, F. W., Hart, R. L., Gazdik, M. M., Bryden, A. M., Snyder, S. A., & Stage, T. G. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.11.0457 · Cited by 85
“Important electrode-muscle output characteristics include the change in muscle force as a function of the muscle length and the change in muscle force output as a function of the stimulus intensity [11].”
BackgroundSelf-citationPena, A. E., Kuntaegowdanahalli, S. S., Abbas, J. J., Patrick, J., Horch, K. W., & Jung, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa814d · Cited by 22
Some aspects of functional neuromuscular stimulation
Devasahayam, S. R. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)87036-t · Cited by 1
Metadata
- Authors
- Kilgore, K. L., Peckham, P. H., Keith, M. W., & Thrope, G. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990
- Volume
- 37
- Issue
- 1
- Pages
- 12-21
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2131433601
- Cited by
- 40
- References
- 3
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.