Recruitment properties of monopolar and bipolar epimysial electrodes
Abstract
Muscle force was studied as a function of stimulus parameters, epimysial electrode position relative to nerve supply, and muscle length to provide insight into the properties of motor prostheses that employ epimysial electrodes. The results of the acute experiments indicated that the dependence of recruitment (force versus stimulus amplitude) on muscle length was minimal for a monopolar electrode positioned close to nerve entrance or 5 mm proximal to the motor point. The selectivity of stimulation (minimal activation of adjacent muscles) was best, and the recruitment rate the highest, for an electrode placed close to the nerve entrance. A bipolar pair of electrodes placed on the superficial surface of the muscle opposite to the nerve entrance gave better selectivity than the monopolar electrode at the low end of the recruitment range, and poorer selectivity at the high end. This electrode configuration required greater stimulus currents and exhibited a lower recruitment gain than was obtained for a monopolar electrode in the same position. Examination of tissue surrounding the electrode 30 days after implantation showed that the fibrous tissue encapsulating the electrode had been incorporated into the fascial layer. Slightly larger dependence on muscle length and lower selectivity of stimulation were measured after encapsulation than were measured in the acute experiments.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Another problem derives from the lack of selective, size-programmed activation of motor units within each muscle, thus limiting the period of use by muscle fatigue.
“Another problem derives from the lack of selective, size-programmed activation of motor units within each muscle, thus limiting the period of use by muscle fatigue”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Grandjean and Mortimer, 1986
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529 · see citing works
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
Self-citationThe effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215 · see citing works
Self-citationOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · see citing works
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Self-citationA slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107 · see citing works
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92 · see citing works
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · see citing works
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
Sweeney, J. D., Crawford, N. R., & Brandon, T. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510525 · Cited by 51 · see citing works
ICFEM 2000. Third IEEE International Conference on Formal Engineering Methods
(2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867869 · Cited by 20 · see citing works
- Authors
- Grandjean, P. A., & Mortimer, J. T.
- Affiliations
- Case Western Reserve University (US)
- ORCID
- Mortimer, J. Thomas
- Venue
- Annals of Biomedical Engineering
- Published
- 1986-01
- Volume
- 14
- Issue
- 1
- Pages
- 53-66
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W1988497775
- Cited by
- 134
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 3 · 2015: 3 · 2014: 3 · 2013: 6 · 2012: 3
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (N01-NS-0-2330)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- monopolar electrodes, bipolar electrodes, muscle recruitment, muscle force, motor points, stimulation selectivity, muscle length, electrode encapsulation, fascia, implantation
- MeSH terms
- Animals, Biomedical Engineering, Cats, Electric Stimulation, Electrodes, Implanted, Humans, Muscle Contraction, Muscles, Neuromuscular Junction, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review