CoChat

Quadrupolar stimulation for cochlear prostheses: modeling and experimental data

Jolly, C.N., Spelman, F.A., Clopton, B.M. · 1996 · IEEE Transactions on Biomedical Engineering
Cited by 132

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Cochlear implants are electrically driven in monopolar, bipolar, or common ground mode. Ideally, a quadrupolar mode is created with three colinear electrodes, where the outer poles are half the inverse polarity value of the center electrode. The resulting field is highly focused. Models of point sources show that the quadrupolar paradigm offers a greater choice of parameters to shape the field. Simulation with a lumped-parameter model of the cochlea confirms the focusing action of the quadrupole in the layers of the inner ear. Field measurements in saline solution and in the scala tympani of guinea pigs show that focusing occurs with the quadrupolar mode. It is conceivable that quadrupolar stimulation will affect the pitch place coding, reduce channel interaction and limit facial or tactile stimulation induced by current spread.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.508549

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 132

Metadata

Authors
Jolly, C. N., Spelman, F. A., & Clopton, B. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1996
Volume
43
Issue
8
Pages
857-865
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2128858948
Cited by
132
References
2
FWCI
1.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.