Quadrupolar stimulation for cochlear prostheses: modeling and experimental data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cochlear implants are electrically driven in monopolar, bipolar, or common ground mode. Ideally, a quadrupolar mode is created with three colinear electrodes, where the outer poles are half the inverse polarity value of the center electrode. The resulting field is highly focused. Models of point sources show that the quadrupolar paradigm offers a greater choice of parameters to shape the field. Simulation with a lumped-parameter model of the cochlea confirms the focusing action of the quadrupole in the layers of the inner ear. Field measurements in saline solution and in the scala tympani of guinea pigs show that focusing occurs with the quadrupolar mode. It is conceivable that quadrupolar stimulation will affect the pitch place coding, reduce channel interaction and limit facial or tactile stimulation induced by current spread.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41
Cited by
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents
Kral, A., Hartmann, R., Mortazavi, D., & Klinke, R. (1998) · Hearing Research · doi:10.1016/s0378-5955(98)00061-6 · Cited by 279
Laser stimulation of the auditory nerve
Izzo, A. D., Richter, C., Jansen, E. D., & Walsh, J. T. (2006) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20358 · Cited by 228
“Further shortcomings of electric stimulation are the spread of current in the tissue [8–11], and the potential mechanical tissue damage caused by”
How cochlear implants encode speech
Rubinstein, J. T. (2004) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/01.moo.0000134452.24819.c0 · Cited by 209
Current focusing and steering: Modeling, physiology, and psychophysics
Bonham, B. H., & Litvak, L. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.006 · Cited by 197
Metadata
- Authors
- Jolly, C. N., Spelman, F. A., & Clopton, B. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1996
- Volume
- 43
- Issue
- 8
- Pages
- 857-865
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2128858948
- Cited by
- 132
- References
- 2
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.