Selective control of muscle activation with a multipolar nerve cuff electrode

Veraart, C., Grill, W.M., Mortimer, J.T.·1993·IEEE Transactions on Biomedical Engineering

Abstract

Acute experiments were performed on adult cats to study selective activation of medial gastrocnemius, soleus, tibialis anterior, and extensor digitorum longus with a cuff electrode. A spiral nerve cuff containing twelve "dot" electrodes was implanted around the sciatic nerve and evoked muscle twitch forces were recorded in six experiments. Spatially isolated "dot" electrodes in four geometries: monopolar, longitudinal tripolar, tripolar with four common anodes, and two parallel tripoles, were combined with transverse field steering current(s) from an anode(s) located 180 degrees around from the cathode(s) to activate different regions of the nerve trunk. To quantify the degree of selectivity, a selectivity index was defined as the ratio of the force in one muscle to the force in all four muscles in response to a particular stimulus. The selectivity index was used to construct recruitment curves for a muscle with the optimal degree of selectivity. Physiological responses were correlated with the anatomical structure of the sciatic nerve by identifying the nerve fascicles innervating the four muscles, and by determining the relative positions of the electrodes and the nerve fascicles. The results indicated that the use of transverse field steering current improved selectivity. We also found that tripoles with individual dot anodes were more selective than tripoles with four common dot anodes. Stimulation with two parallel tripoles was effective in activating selectively fascicl…

Integrity signals

Registry

Crossref · 10.1109/10.237694

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Veraart, C., Grill, W. M., & Mortimer, J. T.
Affiliations
Case Western Reserve University (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1993-07
Volume
40
Issue
7
Pages
640-653
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2075966411
Cited by
320
References
1
Citations by year
2026: 2 · 2025: 3 · 2024: 8 · 2023: 4 · 2022: 6 · 2021: 12 · 2020: 8 · 2019: 7 · 2018: 11 · 2017: 8 · 2016: 7 · 2015: 13 · 2014: 7 · 2013: 11 · 2012: 10
FWCI
1.80
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • DIAL (Catholic University of Leuven) (submittedVersion)
Funders
  • National Institutes of Health (5r01ns026476-03)
  • National Institute of General Medical Sciences (GM 07535, T32GM007535)
  • National Institute of Neurological Disorders and Stroke (NS-26476)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
cuff electrodes, sciatic nerve, tripole, recruitment curves, nerve fascicles, peripheral nerve stimulation
MeSH terms
Animals, Cats, Electric Stimulation, Electrodes, Equipment Design, Isometric Contraction, Muscles, Sciatic Nerve, Sensitivity and Specificity, Time Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review