The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application)
Abstract
For pt.VII see J. Neurosci. Methods, vol.9, p.301-8 (1983). The charge injection limits of a Pt electrode using 0.2 ms charge balanced, biphasic current pulses range from 50 to 150 mu C/cm/sup 2/ geometric if the potential excursions of the electrode are kept below those at which H/sub 2/ or O/sub 2/ are produced. These charge densities are three to ten times smaller than the currently accepted value based on earlier experiments in which the reversible surface reactions were fully utilized and the pulse widths were longer. Several qualifying comments are made regarding the experimental results.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 359
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
Self-citationBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Self-citationBrummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326179 · Cited by 216
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Self-citationElectrical stimulation with Pt electrodes. V. The effect of protein on Pt dissolution
Robblee, L. S., McHardy, J., Marston, J. M., & Brummer, S. B. (1980) · Biomaterials · doi:10.1016/0142-9612(80)90035-6 · Cited by 117
Self-citationRobblee, L. S., McHardy, J., Agnew, W. F., & Bullara, L. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90062-6 · Cited by 95
Self-citationElectrical Stimulation with Pt Electrodes: AMethod for Determination of "Real" Electrode Areas
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326178 · Cited by 91
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 43
Kelliher, E. M., & Rose, T. L. (1987) · MRS Proceedings · doi:10.1557/proc-110-23 · Cited by 28
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Instability of Supported Platinum Nanoparticles in Low-Temperature Fuel Cells
Shao-Horn, Y., Sheng, W. C., Chen, S., Ferreira, P. J., Holby, E. F., & Morgan, D. (2007) · Topics in Catalysis · doi:10.1007/s11244-007-9000-0 · Cited by 939
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Metadata
- Authors
- Rose, T. L., & Robblee, L. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990
- Volume
- 37
- Issue
- 11
- Pages
- 1118-1120
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2016006796
- Cited by
- 358
- References
- 10
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application). https://app.cochat.ai/papers/10.1109/10.61038
- The paper
- Rose, T. L., & Robblee, L. S. (1990). Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application). IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.61038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.