The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application)
Abstract
For pt.VII see J. Neurosci. Methods, vol.9, p.301-8 (1983). The charge injection limits of a Pt electrode using 0.2 ms charge balanced, biphasic current pulses range from 50 to 150 mu C/cm/sup 2/ geometric if the potential excursions of the electrode are kept below those at which H/sub 2/ or O/sub 2/ are produced. These charge densities are three to ten times smaller than the currently accepted value based on earlier experiments in which the reversible surface reactions were fully utilized and the pulse widths were longer. Several qualifying comments are made regarding the experimental results.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 359
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
Self-citationBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Self-citationBrummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326179 · Cited by 216
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Self-citationElectrical stimulation with Pt electrodes. V. The effect of protein on Pt dissolution
Robblee, L. S., McHardy, J., Marston, J. M., & Brummer, S. B. (1980) · Biomaterials · doi:10.1016/0142-9612(80)90035-6 · Cited by 126
Self-citationRobblee, L. S., McHardy, J., Agnew, W. F., & Bullara, L. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90062-6 · Cited by 104
Self-citationElectrical Stimulation with Pt Electrodes: AMethod for Determination of "Real" Electrode Areas
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326178 · Cited by 91
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 45
Kelliher, E. M., & Rose, T. L. (1987) · MRS Proceedings · doi:10.1557/proc-110-23 · Cited by 30
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
“Rose and Robblee (1990) reported on the charge injection limits for a platinum electrode using 200 s charge-balanced biphasic pulses.”
BackgroundYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Instability of Supported Platinum Nanoparticles in Low-Temperature Fuel Cells
Shao-Horn, Y., Sheng, W. C., Chen, S., Ferreira, P. J., Holby, E. F., & Morgan, D. (2007) · Topics in Catalysis · doi:10.1007/s11244-007-9000-0 · Cited by 939
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Highly Conducting and Stretchable Double‐Network Hydrogel for Soft Bioelectronics
Li, G., Huang, K., Deng, J., Guo, M., Cai, M., Zhang, Y., & Guo, C. F. (2022) · Advanced Materials · doi:10.1002/adma.202200261 · Cited by 443
Neural Stimulation with a Carbon Nanotube Microelectrode Array
Wang, K., Fishman, H. A., Dai, H., & Harris, J. S. (2006) · Nano Letters · doi:10.1021/nl061241t · Cited by 415
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.023 · Cited by 335
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
Sensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Poly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation
Cui, X. T., & Zhou, D. D. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.909811 · Cited by 277
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation
Luo, X., Weaver, C. L., Zhou, D. D., Greenberg, R., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.051 · Cited by 252
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016) · Scientific Reports · doi:10.1038/srep33526 · Cited by 213
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
“Pulse durations were chosen according to previously repor t d values for evaluation of the electrochemical properties of neural electrodes [29, 30].”
MethodPrado-Guitierrez, P., Fewster, L. M., Heasman, J. M., McKay, C. M., & Shepherd, R. K. (2006) · Hearing Research · doi:10.1016/j.heares.2006.03.006 · Cited by 173
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162
“The anticipated charge-injection requirements for stimulation of the central nervous system exceed the established limits of noble metal electrodes [5], and most studies involving intracortical stimulation employ activated iridium oxide electrodes (AIROF) that provide significantly higher levels of reversible charge-i…”
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
“A study of brief pulses injected through platinum electrodes (Rose and Robblee, 1990) measured a conservative charge density limit of 0.1– 0.15 mC/cm 2 (cathodal-first biphasic) or 0.05– 0.1 mC/cm 2 (anodal-first biphasic).”
BackgroundInfluentialCurrent steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Weremfo, A., Carter, P., Hibbert, D. B., & Zhao, C. (2015) · Langmuir · doi:10.1021/la504876n · Cited by 59
Bionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49
Stretchable gold nanowire-based cuff electrodes for low-voltage peripheral nerve stimulation
Lienemann, S., Zötterman, J., Farnebo, S., & Tybrandt, K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfebb · Cited by 48
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43
Brunton, E. K., Winther-Jensen, B., Wang, C., Yan, E. B., Hagh Gooie, S., Lowery, A. J., & Rajan, R. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00265 · Cited by 46
Boretius, T., Yoshida, K., Badia, J., Harreby, K., Kundu, A., Navarro, X., Jensen, W., & Stieglitz, T. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290787 · Cited by 39
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
Muceli, S., Poppendieck, W., Hoffmann, K.-P., Dosen, S., Benito-León, J., Barroso, F. O., Pons, J. L., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab047a · Cited by 33
Does a coupling capacitor enhance the charge balance during neural stimulation? An empirical study
van Dongen, M. N., & Serdijn, W. A. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1312-9 · Cited by 23
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073130 · Cited by 18
High-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
Analysis of passive charge balancing for safe current-mode neural stimulation
Rueda, G. L. E., Ballini, M., Van Hellepute, N., & Mitra, S. (2017) · 2017 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2017.8050621 · Cited by 11
“The second, VCdl , does not include the IR drop in the tissue and, although not accessible for direct measurement, is relevant for reversible charge injection, where a limit is imposed by the water window [19].”
Background
Metadata
- Authors
- Rose, T. L., & Robblee, L. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990
- Volume
- 37
- Issue
- 11
- Pages
- 1118-1120
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2016006796
- Cited by
- 358
- References
- 10
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.