Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach
The DOI matches its Crossref record.
Abstract
A polarimetric glucose sensor utilizing a digital closed-loop controller was designed and implemented during this study. Its potential as a noninvasive glucose sensor was evaluated in vitro for both glucose-doped water and bovine aqueous humor mediums. A physiological hyperglycemic concentration range was used in both calibration and validation of each set of experiments. Ideally, the end application of this system could estimate blood glucose concentrations indirectly by measuring the amount of rotation of a light beam's polarization state after it propagates through the aqueous humor contained within the anterior chamber of the eye. The polarimeter designed in this study differs from similar investigated systems in that it utilizes a digital closed-loop control system. This type of controller was implemented in order to further improve system repeatability and stability without sacrificing accuracy. Unique to this investigation, independent validation sets other than those used to create each respective calibration model were obtained. The results of the glucose-doped water experiments yielded mean standard errors of prediction for calibration and validation of 6.91 and 8.84 mg/dl, respectively. The mean standard errors of prediction during calibration and validation of the glucose-doped aqueous humor experiments were higher at 27.20 and 27.47 mg/dl, respectively, due to medium degradation over time while exposed to air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 371
Self-citationGhosh, N., Wood, M. F. G., & Vitkin, I. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2960934 · Cited by 265
Multicomponent blood analysis by near-infrared Raman spectroscopy
Berger, A. J., Koo, T.-W., Itzkan, I., Horowitz, G., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.002916 · Cited by 255
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Güçlü, B., Engbretson, G. A., & Bolanowski, S. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1780542 · Cited by 7
Metadata
- Authors
- Cameron, B. D., & Cote, G. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 12
- Pages
- 1221-1227
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2132992425
- Cited by
- 112
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.