Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Abstract
A microscale membrane-less biofuel cell, capable of generating electrical energy from human lachrymal liquid, was developed by utilizing the ascorbate and oxygen naturally present in tears as fuel and oxidant. The biodevice is based on three-dimensional nanostructured gold electrodes covered with abiotic (conductive organic complex) and biological (redox enzyme) materials functioning as efficient anodic and cathodic catalysts, respectively. Three-dimensional nanostructured electrodes were fabricated by modifying 100 μm gold wires with 17 nm gold nanoparticles, which were further modified with tetrathiafulvalene-tetracyanoquinodimethane conducting complex to create the anode and with Myrothecium verrucaria bilirubin oxidase to create the biocathode. When operated in human tears, the biodevice exhibited the following characteristics: an open circuit voltage of 0.54 V, a maximal power density of 3.1 μW cm(-2) at 0.25 V and 0.72 μW cm(-2) at 0.4 V, with a stable current density output of over 0.55 μA cm(-2) at 0.4 V for 6 h of continuous operation. These findings support our proposition that an ascorbate/oxygen biofuel cell could be a suitable power source for glucose-sensing contact lenses to be used for continuous health monitoring by diabetes patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wearable biofuel cells are promising for powering non-invasive wearable platforms.
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [193]
Wearable biofuel cells harvest energy from the same biofluids of interest.
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [193]
Wearable biofuel cells can operate as self-powered biosensors.
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [193]
Wearable biofuel cells still suffer from stability issues.
“Wearable biofuel cells, in particular, are promising for the powering of non-invasive wearable platforms as they harvest energy from the same biofluids of interest and can operate as self-powered biosensors, but yet still suffer from the same stability issues discussed above42,193,194.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [193]
Cites
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
Frens, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,373 · see citing works
Hex, N., Bartlett, C., Wright, D., Taylor, M., & Varley, D. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2012.03698.x · Cited by 819 · see citing works
Direct electron transfer between copper-containing proteins and electrodes
Shleev, S., Tkáč, J., Christenson, A., Ruzgas, T. A., Yaropolov, A. I., Whittaker, J. W., & Gorton, L. G. O. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.003 · Cited by 622 · see citing works
Self-citationXu, F., Shin, W., Brown, S. H., Wahleithner, J. A., Sundaram, U. M., & Solomon, E. I. (1996) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/0167-4838(95)00210-3 · Cited by 557 · see citing works
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · see citing works
Photonic Crystal Carbohydrate Sensors: Low Ionic Strength Sugar Sensing
Asher, S. A., Alexeev, V. L., Goponenko, A. V., Sharma, A. C., Lednev, I. K., Wilcox, C. S., & Finegold, D. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021037h · Cited by 487 · see citing works
Berman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 476 · see citing works
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372 · see citing works
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · see citing works
Tsubota, K. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00004-4 · Cited by 357 · see citing works
Fast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292 · see citing works
Ultra Low Power Bioelectronics
Sarpeshkar, R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511841446 · Cited by 290 · see citing works
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279 · see citing works
Direct electron transfer based enzymatic fuel cells
Falk, M., Blum, Z., & Shleev, S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2011.12.133 · Cited by 251 · see citing works
Self-citationSelf-assembled single-crystal silicon circuits on plastic
Stauth, S. A., & Parviz, B. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602893103 · Cited by 215 · see citing works
Biofuel cell as a power source for electronic contact lenses
Falk, M., Andoralov, V., Blum, Z., Sotres, J., Suyatin, D. B., Ruzgas, T. A., Arnebrant, T., & Shleev, S. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.04.030 · Cited by 211 · see citing works
Self-citationdos Santos, L., Climent, V., Blanford, C. F., & Armstrong, F. A. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp00018c · Cited by 205 · see citing works
Gold Nanoparticles as Electronic Bridges for Laccase-Based Biocathodes
Gutiérrez‐Sánchez, C., Pita, M., Vaz‐Domínguez, C., et al. (2012) · Journal of the American Chemical Society · doi:10.1021/ja307308j · Cited by 204 · see citing works
Murata, K., Kajiya, K., Nakamura, N., & Ohno, H. (2009) · Energy & Environmental Science · doi:10.1039/b912915d · Cited by 188 · see citing works
A survey of the energy transformations in living matter
Krebs, H. A., Kornberg, H. L., & Burton, K. (1957) · Reviews of physiology, biochemistry and pharmacology · doi:10.1007/bf02269485 · Cited by 188 · see citing works
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187 · see citing works
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173 · see citing works
Glucose-Sensitive Holographic Sensors for Monitoring Bacterial Growth
Lee, M., Kabilan, S., Hussain, A., Yang, X., Blyth, J., & Lowe, C. R. (2004) · Analytical Chemistry · doi:10.1021/ac049334n · Cited by 167 · see citing works
A Direct Electron Transfer‐Based Glucose/Oxygen Biofuel Cell Operating in Human Serum
Coman, V., Ludwig, R., Harreither, W., Haltrich, D., Gorton, L., Ruzgas, T. A., & Shleev, S. (2009) · Fuel Cells · doi:10.1002/fuce.200900121 · Cited by 167 · see citing works
Self-citationIn Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy
Maruo, K., Tsurugi, M., Tamura, M., & Ozaki, Y. (2003) · Applied Spectroscopy · doi:10.1366/000370203769699090 · Cited by 162 · see citing works
Moussy, F. G., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V. (1993) · Analytical Chemistry · doi:10.1021/ac00063a023 · Cited by 158 · see citing works
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157 · see citing works
Ramírez, P., Mano, N., Andreu, R., Ruzgas, T. A., Heller, A., Gorton, L. G. O., & Shleev, S. (2008) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2008.06.010 · Cited by 152 · see citing works
Self-citationA single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148 · see citing works
Shleev, S., Kasmi, A. E., Ruzgas, T. A., & Gorton, L. G. O. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.07.008 · Cited by 137 · see citing works
Self-citationWater-soluble antioxidants in human tears: effect of the collection method.
Choy, C. K. M., Cho, P., Chung, W.-Y., & Benzie, I. F. F. (2001) · PubMed · Cited by 116 · see citing works
Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach
Cameron, B. D., & Cote, G. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649993 · Cited by 113 · see citing works
Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
Baca, J. T., Taormina, C. R., Feingold, E., Finegold, D. N., Grabowski, J. J., & Asher, S. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078543 · Cited by 110 · see citing works
A glucose-sensing contact lens: from bench top to patient
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.007 · Cited by 105 · see citing works
Yang, X., Pan, X., Blyth, J., & Lowe, C. R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.09.016 · Cited by 103 · see citing works
High Redox Potential Cathode Based on Laccase Covalently Attached to Gold Electrode
Pita, M., Gutiérrez‐Sánchez, C., Olea, D., Vélez, M., García-Diego, C., Shleev, S., Fernández, V. M., & Lacey, A. L. D. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp203643h · Cited by 101 · see citing works
Self-citationAnalysis of tear glucose concentration with electrospray ionization mass spectrometry
Taormina, C. R., Baca, J. T., Asher, S. A., Grabowski, J. J., & Finegold, D. N. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.002 · Cited by 99 · see citing works
Direct electron transfer catalyzed by bilirubin oxidase for air breathing gas-diffusion electrodes
Gupta, G., Lau, C., Rajendran, V., Colon, F., Branch, B. A., Ivnitski, D. M., & Atanassov, P. B. (2011) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.12.024 · Cited by 97 · see citing works
Tear fluid content of electrochemically active components including water soluble antioxidants
GOGIA, R., RICHER, S. P., & Rose, R. C. (1998) · Current Eye Research · doi:10.1076/ceyr.17.3.257.5213 · Cited by 89 · see citing works
Yeh, S.-J., Hanna, C. F., & Khalil, O. S. (2003) · Clinical Chemistry · doi:10.1373/49.6.924 · Cited by 79 · see citing works
Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric Sensing
Kagie, A., Bishop, D. K., Burdick, J., Belle, J. T. L., Dymond, R., Felder, R. A., & Wang, J. (2008) · Electroanalysis · doi:10.1002/elan.200804253 · Cited by 77 · see citing works
Haeringen, N. J. V., & Glasius, E. (1977) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00496763 · Cited by 75 · see citing works
Choy, C. K. M., Benzie, I. F. F., & Cho, P. (2000) · PubMed · Cited by 68 · see citing works
Design of a Biosensor for Continual, Transdermal Glucose Monitoring
Tierney, M. J., Jayalakshmi, Y., Parris, N. A., Reidy, M. P., Uhegbu, C. E., & Vijayakumar, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1681 · Cited by 59 · see citing works
Optical-transparent and flexible glucose sensor with ITO electrode
Mitsubayashi, K., Wakabayashi, Y., Tanimoto, S., Murotomi, D., & Endo, T. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00130-1 · Cited by 58 · see citing works
Shleev, S., Shumakovich, G. P., Morozova, O. V., et al. (2010) · Fuel Cells · doi:10.1002/fuce.200900191 · Cited by 48 · see citing works
Self-citationConductive Organic Complex Salt TTF‐TCNQ as a Mediator for Biosensors. An Overview
Pauliukaitė, R., Malinauskas, A., Zhylyak, G., et al. (2007) · Electroanalysis · doi:10.1002/elan.200704035 · Cited by 38 · see citing works
Johnson, A. T. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.12.1809-b · Cited by 38 · see citing works
A hybrid biofuel cell based on electrooxidation of glucose using ultra-small silicon nanoparticles
Choi, Y., Wang, G., Nayfeh, M. H., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.032 · Cited by 35 · see citing works
Xing, X., Shao, M., Hsiao, M. W., et al. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80453-b · Cited by 31 · see citing works
A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring
Chu, M. K., Kudo, H., Shirai, T., Miyajima, K., Saito, H., Morimoto, N., Yano, K., Iwasaki, Y., Akiyoshi, K., & Mitsubayashi, K. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9300-1 · Cited by 31 · see citing works
A flexible biosensor for glucose
Mitsubayashi, K., Dicks, J. M., Yokoyama, K., Takeuchi, T., Tamiya, E., & Karube, I. (1995) · Electroanalysis · doi:10.1002/elan.1140070110 · Cited by 27 · see citing works
Ivanov, I. B., Vidaković-Koch, T. R., & Sundmacher, K. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.07.060 · Cited by 25 · see citing works
Dopamine and Its Metabolites in Human Tears
Martin, X. D., & Brennan, M. C. (1993) · European Journal of Ophthalmology · doi:10.1177/112067219300300206 · Cited by 23 · see citing works
Kulys, J. J., Simkeviciene, V., & Higgins, I. J. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)80006-w · Cited by 19 · see citing works
Impact of the Gold Support on the Electrocatalytic Oxidation of Sugars at Enzyme‐Modified Electrodes
Vidaković-Koch, T. R., Ivanov, I. B., Falk, M., et al. (2011) · Electroanalysis · doi:10.1002/elan.201000639 · Cited by 13 · see citing works
Self-citationImmunology of the lacrimal gland, tear film and ocular surface
Berry, M. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.073890 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · see citing works
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · see citing works
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315 · see citing works
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237 · see citing works
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193 · see citing works
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135 · see citing works
Self-citationA passive perspiration biofuel cell: High energy return on investment
Yin, L., Moon, J.-M., Sempionatto, J. R., Lin, M., Cao, M., Trifonov, A., Zhang, F., Lou, Z., Jeong, J.-M., Lee, S.-J., et al. (2021) · Joule · doi:10.1016/j.joule.2021.06.004 · Cited by 134 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
- Authors
- Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S.
- Affiliations
- Malmö University (SE)
- Novozymes (Denmark) (DK)
- Corresponding author
- Shleev, Sergey
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-19
- Volume
- 85
- Issue
- 13
- Pages
- 6342-6348
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973856370
- Cited by
- 173
- References
- 57
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 14 · 2023: 17 · 2022: 13 · 2021: 16 · 2020: 17 · 2019: 20 · 2018: 14 · 2017: 18 · 2016: 14 · 2015: 9 · 2014: 11
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Malmö University Publications (Malmö University) (submittedVersion)
- Funders
- European Commission
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Keywords
- biofuel cells, human tears, bilirubin oxidase, Myrothecium verrucaria, gold nanoparticles, nanostructured electrodes, diabetes monitoring, continuous glucose monitoring, wearable biosensors
- MeSH terms
- Bioelectric Energy Sources, Contact Lenses, Glucose, Humans, Male, Miniaturization, Tears, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review