The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A critical analysis of linear inverse solutions to the neuroelectromagnetic inverse problem
Abstract
This paper explores the possibilities of using linear inverse solutions to reconstruct arbitrary current distributions within the human brain. We formally prove that due to the underdetermined character of the problem, the only class of measurable current distributions that can be totally retrieved are those of minimal norm. The reconstruction of smooth or averaged versions of the currents is also explored. A solution that explicitly attempts to reconstruct averages of the current is proposed and compared with the minimum norm and the minimum Laplacian solution. In contrast to the majority of previous analysis carried out in the field, in the comparisons, we avoid the use of measures designed for the case of dipolar sources. To allow for the evaluation of distributed solutions in the case of arbitrary current distributions we use the concept of resolution kernels. Two summarizing measures, source identifiability and source visibility, are proposed and applied to the comparison. From this study can be concluded: 1) linear inverse solutions are unable to produce adequate estimates of arbitrary current distributions at many brain sites and 2) averages or smooth solutions are better than the minimum norm solution estimating the position of single point sources. However, they systematically underestimate their amplitude or strength especially for the deeper brain areas. Based on these result, it appears unlikely that a three-dimensional (3-D) tomography of the brain electromagnetic activity can be based on linear reconstruction methods without the use of a significant amount of a priori information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Cited by
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Dynamic causal modeling of evoked responses in EEG and MEG
David, O., Kiebel, S. J., Harrison, L. M., Mattout, J., Kilner, J. M., & Friston, K. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.045 · Cited by 620
Lin, F.-H., Witzel, T., Ahlfors, S. P., Stufflebeam, S. M., Belliveau, J. W., & Hämäläinen, M. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.054 · Cited by 505
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
A Quantitative Assessment of the Sensitivity of Whole-Head MEG to Activity in the Adult Human Cortex
Hillebrand, A., & Barnes, G. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1102 · Cited by 428
Electrical neuroimaging based on biophysical constraints
Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R., & Gonzalez Andino, S. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 365
Self-citationMonte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Menendez, R. G. D. P., Andino, S. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 348
A critical assessment of connectivity measures for EEG data: A simulation study
Haufe, S., Nikulin, V. V., Müller, K.-R., & Nolte, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.036 · Cited by 334
Hauk, O. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.018 · Cited by 300
Hierarchical Bayesian estimation for MEG inverse problem
Sato, M.-A., Yoshioka, T., Kajihara, S., Toyama, K., Goda, N., Doya, K., & Kawato, M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.037 · Cited by 275
Effect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
Neuroelectromagnetic correlates of perceptual closure processes
Grutzner, C., Uhlhaas, P. J., Genc, E., Kohler, A., Singer, W., & Wibral, M. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5434-09.2010 · Cited by 77
Imperatori, C., Valenti, E. M., Della Marca, G., Amoroso, N., Massullo, C., Carbone, G. A., Maestoso, G., Quintiliani, M. I., Contardi, A., & Farina, B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.010 · Cited by 29
Electrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Metadata
- Authors
- De Peralta-Menendez, R. G., & Gonzalez-Andino, S. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998-04
- Volume
- 45
- Issue
- 4
- Pages
- 440-448
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2099655817
- Cited by
- 175
- References
- 7
- FWCI
- 15.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.