The artificial excitation process of neurons of the central nervous system depends on the applied extracellular field, on the geometry of the neuron and on the electrical properties of the neural subunits. Results of computer simulations are based on a compartment model of the neuron and its equivalent electrical network. Furthermore, a theory is presented which generalizes the activating function concept known from peripheral nerve stimulation. The theory predicts the influence of electrical and geometrical parameters on the excitation threshold. Generally, the myelinated axon is the part of a neuron which is most excitable to a given applied field. An example demonstrates that for a target neuron the quotient (anodic threshold current)/(cathodic threshold current) essentially depends on the position and orientation of the neuron relative to the electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681 · cited 3×
“Thus we obtain a system of differential equations to calculate the voltage distribution caused by an extracellular stimulus (for details, see [14]–[16])”
Self-citationRattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Self-citationModeling axon membranes for functional electrical stimulation
Rattay, F., & Aberham, M. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250575 · Cited by 174
Self-citation
Cited by
Endogenous electric fields may guide neocortical network activity
Fröhlich, F., & McCormick, D. A. (2010) · Neuron · doi:10.1016/j.neuron.2010.06.005 · Cited by 913
Selection of stimulus parameters for deep brain stimulation
Kuncel, A. M., & Grill, W. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.05.031 · Cited by 458
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
How the brain tissue shapes the electric field induced by transcranial magnetic stimulation
Opitz, A., Windhoff, M., Heidemann, R. M., Turner, R., & Thielscher, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.069 · Cited by 360
Mechanisms of action of deep brain stimulation (DBS)
Montgomery, E. B., & Gale, J. T. (2008) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2007.06.003 · Cited by 344
“Biophysical analysis confirms that presynaptic terminals are most sensitive to electrical stimulation (Rattay, 1998).”
BackgroundTissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.023 · Cited by 335
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
Excitation of Central Nervous System Neurons by Nonuniform Electric Fields
McIntyre, C. C., & Grill, W. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77251-6 · Cited by 319
Radman, T., Su, Y., An, J. H., Parra, L. C., & Bikson, M. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0095-07.2007 · Cited by 294
Selective Microstimulation of Central Nervous System Neurons
McIntyre, C. C., & Grill, W. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.262 · Cited by 258
Ladenbauer, J., Minassian, K., Hofstoetter, U. S., Dimitrijevic, M. R., & Rattay, F. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2054112 · Cited by 222
“The immediate membrane voltage change of each node and internode in response to an externally applied field can be estimated with the activating function (8) [19], [37]”
Self-citationA model of the electrically excited human cochlear neuron
Rattay, F., Lutter, P., & Felix, H. (2001) · Hearing Research · doi:10.1016/s0378-5955(00)00256-2 · Cited by 219
Self-citationRattay, F., Minassian, K., & Dimitrijevic, M. (2000) · Spinal Cord · doi:10.1038/sj.sc.3101039 · Cited by 216
Self-citationElectroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Bungert, A., Antunes, A., Espenhahn, S., & Thielscher, A. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhw292 · Cited by 160
“This is the most commonly used assumption and is based on the observation that the many bends and terminals of axons in GM are likely to represent low-threshold points (Maccabee et al. 1993, 1998; Rattay 1998; Ilmoniemi et al. 1999) and do not have strong preferences in their spatial alignment.”
MethodPrinciples of electrical stimulation of neural tissue
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00001-2 · Cited by 151
Energy-optimal electrical-stimulation pulses shaped by the least-action principle
Krouchev, N. I., Danner, S. M., Vinet, A., Rattay, F., & Sawan, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090480 · Cited by 29
Self-citation
Metadata
- Authors
- Rattay, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998-06
- Volume
- 45
- Issue
- 6
- Pages
- 766-772
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2101421212
- Cited by
- 89
- References
- 4
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.