Multisite microprobes for neural recordings
The DOI matches its Crossref record.
Abstract
Multisite, passive microprobes have been developed to allow simultaneous recording of action potential activity from multiple neurons at different locations in the brain. The microprobes were fabricated using standard integrated circuit techniques. The probe is a planar structure that consists of gold electrodes sandwiched between two polyimide dielectric layers and bonded to a molybdenum structural support. Windows in the top dielectric layer expose the electrode sites and bonding pads. In two distinct versions of the probe four or six recordings sites, respectively, of approximately 25 microns 2 are arranged on a dagger-shaped structure which can penetrate the pia. The bonding pads and interconnect wires at the probe head are entirely encapsulated in a tubular fixture that is packed with silicone RTV and sealed with epoxy to protect the interconnections from contact with body fluids. The site impedances at 1 kHz are typically between 2 and 4 M omega. Probe lifetimes for continuous immersion in physiological saline solution, as measured by impedance, have exceeded 750 h. The failure mechanism is believed to be due to moisture and ion absorption in the top dielectric layer. In acute neurophysiological experiments using the four site probes, action potential activity was recorded from physiologically identified neurons in the dorsal column nuclei of anesthetized rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
“have been created from silicon, [2], [11], [12], or incorporate molybdenum [13]; materials that are stiff enough to penetrate the pia upon implantation.”
BackgroundCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Metadata
- Authors
- Blum, N. A., Carkhuff, B. G., Charles, H. K., Edwards, R. L., & Meyer, R. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 1
- Pages
- 68-74
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2093839040
- Cited by
- 93
- References
- 0
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multisite microprobes for neural recordings. https://app.cochat.ai/papers/10.1109/10.68211
- The paper
- Blum, N. A., Carkhuff, B. G., Charles, H. K., Edwards, R. L., & Meyer, R. A. (1991). Multisite microprobes for neural recordings. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.68211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.