The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Spatial filtering and neocortical dynamics: estimates of EEG coherence
Open accessAbstract
The spatial statistics of scalp electroencephalogram (EEG) are usually presented as coherence in individual frequency bands. These coherences result both from correlations among neocortical sources and volume conduction through the tissues of the head. The scalp EEG is spatially low-pass filtered by the poorly conducting skull, introducing artificial correlation between the electrodes. A four concentric spheres (brain, CSF, skull, and scalp) model of the head and stochastic field theory are used here to derive an analytic estimate of the coherence at scalp electrodes due to volume conduction of uncorrelated source activity, predicting that electrodes within 10-12 cm can appear correlated. The surface Laplacian estimate of cortical surface potentials spatially bandpass filters the scalp potentials reducing this artificial coherence due to volume conduction. Examination of EEG data confirms that the coherence estimates from raw scalp potentials and Laplacians are sensitive to different spatial bandwidths and should be used in parallel in studies of neocortical dynamic function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Self-citationElectric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320380071046 · Cited by 1,543
Probabilistic Theory of Structural Dynamics
Lin, Y.-K. M. (1976) · Medical Entomology and Zoology · Cited by 1,398
Nunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225
Self-citationNeocortical Dynamics and Human EEG Rhythms
Nunez, P. L., & Williamson, S. J. (1996) · Physics Today · doi:10.1063/1.2807585 · Cited by 1,001
Self-citationNeocortical Dynamics and Human EEG Rhythms
Collura, T. F. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00010 · Cited by 892
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751
Cortico-cortical associations and EEG coherence: A two-compartmental model
Thatcher, R. W., Krause, P. J., & Hrybyk, M. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90107-0 · Cited by 628
Random Data: Analysis and Measurement Procedures.
Chatfield, C., Bendat, J. S., & Piersol, A. G. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981634 · Cited by 571
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
Nunez, P. L., Silberstein, R. B., Cadusch, P. J., Wijesinghe, R. S., Westdorp, A. F., & Srinivasan, R. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90112-0 · Cited by 421
Self-citationA theoretical justification of the average reference in topographic evoked potential studies
Bertrand, O., Perrin, F., & Pernier, J. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90058-9 · Cited by 416
The brain wave equation: a model for the EEG
Nunez, P. L. (1974) · Mathematical Biosciences · doi:10.1016/0025-5564(74)90020-0 · Cited by 336
Self-citationCommon reference coherence data are confounded by power and phase effects
Fein, G., Raz, J., Brown, F. F., & Merrin, E. L. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90171-x · Cited by 287
Comparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
Spatial sampling and filtering of EEG with spline Laplacians to estimate cortical potentials
Srinivasan, R., Nunez, P. L., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1996) · Brain Topography · doi:10.1007/bf01186911 · Cited by 244
Self-citationFrequency dependence of the transmission of the EEG from cortex to scalp
Pfurtscheller, G., & Cooper, R. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90215-1 · Cited by 237
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Self-citationThickness and resistivity variations over the upper surface of the human skull
Law, S. K. (1993) · Brain Topography · doi:10.1007/bf01191074 · Cited by 208
Functional connections among cortical regions: topography of EEG coherence
Tucker, D. M., Roth, D. L., & Bair, T. B. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90092-1 · Cited by 183
A model of the spatial-temporal characteristics of the alpha rhythm
van Rotterdam, A., Lopes da Silva, F. H., van den Ende, J., Viergever, M. A., & Hermans, A. J. (1982) · Bulletin of Mathematical Biology · doi:10.1007/bf02463252 · Cited by 181
High-resolution EEG using spline generated surface Laplacians on spherical and ellipsoidal surfaces
Law, S. K., Nunez, P. L., & Wijesinghe, R. S. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.212068 · Cited by 173
Self-citationThe influence of model parameters on EEG/MEG single dipole source estimation
Stok, C. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326090 · Cited by 172
Generation of human EEG by a combination of long and short range neocortical interactions
Nunez, P. L. (1989) · Brain Topography · doi:10.1007/bf01129583 · Cited by 164
Self-citationBullock, T. H., Mcclune, M. C., Achimowicz, J. Z., Iragui-Madoz, V. J., Duckrow, R. B., & Spencer, S. S. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)93347-a · Cited by 163
A random dipole model for spontaneous brain activity
de Munck, J. C., Vijn, P. C. M., & Lopes, F. H. D. S. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.148387 · Cited by 103
Zhou, H., & van Oosterom, A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121646 · Cited by 68
The Contributions of Intracerebral Currents to the EEG and Evoked Potentials
Hosek, R. S., Sances, A., Jodat, R. W., & Larson, S. J. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326337 · Cited by 61
Biggins, C. A., Fein, G., Raz, J. A., & Amir, A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90206-j · Cited by 54
Statistical mechanics of multiple scales of neocortical interactions
Ingber, L. (1995) · CogPrints (University of Southampton) · Cited by 40
Measurement processes and spatial principal components analysis
Silberstein, R. B., & Cadusch, P. J. (1992) · Brain Topography · doi:10.1007/bf01135564 · Cited by 31
Self-citationComparison of high resolution EEG methods having different theoretical bases
Nunez, P. L., Silberstein, R. B., Cadusch, P. J., & Wijesinghe, R. S. (1993) · Brain Topography · doi:10.1007/bf01128691 · Cited by 26
Self-citation
Cited by
Nunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225
Self-citationA brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Destexhe, A., Contreras, D., & Steriade, M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-11-04595.1999 · Cited by 573
Metadata
- Authors
- Srinivasan, R., Nunez, P. L., & Silberstein, R. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998-07
- Volume
- 45
- Issue
- 7
- Pages
- 814-826
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2095590015
- Cited by
- 325
- References
- 34
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.