Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femoris
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The effects of placement of a miniature implantable stimulator on motor unit recruitment were examined in the posterior head of cat biceps femoris. The implantable stimulator (13-mm long x 2-mm diameter) was injected either proximally near the main nerve branch, or distally near the muscle insertion, through a 12-gauge hypodermic needle. Glycogen-depletion methods were used to map the distribution of fibers activated by electrical stimulation. Muscle fibers were found to be depleted at most or all proximodistal levels of the muscle, but the density of depleted fibers varied transversely according to the stimulus strength and proximity of the device to the nerve-entry site. Thus, muscle cross sections often had a "patchy" appearance produced because different proportions of depleted fibers intermingled with undepleted fibers in different parts of the cross section. In other preparations, the force of muscle contraction was measured when stimuli of varying strengths were delivered by the stimulator positioned at the same proximal or distal sites within the muscle. Devices placed close to the nerve-entry site produced the greatest forces. Those placed more distally produced less force. As stimulus current and/or pulse width increased, muscle force increased, often in steps, until a maximum was reached, which was usually limited by the compliance voltage of the device to less than the force produced by whole nerve stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“that can be inserted percutaneously into muscles [7], [8], or surgically implanted, RF-controlled multichannel stimulators whose wire electrodes are attached either to the surface of the muscle (epimysial) [9] or around the muscle nerve (epineural) [ 10 ], [11].”
BackgroundCrago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133
Cited by
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118
First clinical experience with BION implants for therapeutic electrical stimulation
Salter, A.-C. D., Bagg, S. D., Creasy, J. L., Romano, C., Romano, D., Richmond, F. J. R., & Loeb, G. E. (2004) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2004.04005.x · Cited by 66
Self-citation(2000) · PubMed · Cited by 50
Metadata
- Authors
- Cameron, T., Richmond, F. J. R., & Loeb, G. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998
- Volume
- 45
- Issue
- 8
- Pages
- 1036-1043
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2168257532
- Cited by
- 49
- References
- 2
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.