The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Abstract
The effect of stimulus parameters on the recruitment characteristics of motor nerve was studied for regulated current monophasic and balanced charge biphasic stimuli. Results of a nerve model investigation indicated that the threshold difference between different diameter nerve fibers would be dependent on pulse width, the choice between monophasic and biphasic stimuli, and the delay between the primary cathodic and secondary anodic pulses. Threshold difference increased with decreasing pulse width, the greatest effects evident for pulses less than 100 μs. Biphasic stimulation with no delay between pulses provided greater threshold separation than monophasic stimulation or biphasic stimulation with delay. Animal experiments, in which recruitment in a nerve trunk composed of mixed diameter nerve fibers was examined, showed a decrease in recruitment slope with a decrease in pulse width and with the use of a biphasic, zero delay pulse. These results were examined through muscle force measurements using both a metal loop electrode encircling the nerve trunk and a nerve cuff electrode, i. e., a loop electrode in an insulating tube.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Modification of pulse duration can allow for spatial selectivity and steeper recruitment curves.
“Modification of the pulse duration can allow for spatial selectivity and steeper recruitment curves [75].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [75]
Safety of acute and chronic peripheral nerve stimulation has been demonstrated in animals and humans for pulse durations from 1 to 300 μs for motor function and sensory feedback.
“The safety of acute and chronic peripheral nerve stimulation has been demonstrated in animals and humans for pulse durations from 1 to 300 μs for the purpose of motor function and sensory feedback [43, 44, 75]”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [75]
Gorman and Mortimer confirmed these results, observing steeper recruitment curves and lower threshold currents with increasing interphase delay.
“Gorman and Mortimer confirmed these results, observing steeper recruitment curves (stimulus current vs normalized force) and lower threshold currents with increasing interphase delay [75].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [75]
A large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s.
“Consequently, a large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s [43–45, 62–64, 75, 92, 94, 96, 99, 100].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [75]
Cites
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833 · see citing works
FRANKENHAEUSER, B., & Huxley, A. F. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007378 · Cited by 702 · see citing works
Numbers and contraction-values of individual motor-units examined in some muscles of the limb
Eccles, J. C., & Sherrington, C. (1930) · Proceedings of the Royal Society of London Series B Containing Papers of a Biological Character · doi:10.1098/rspb.1930.0032 · Cited by 377 · see citing works
Composition of Peripheral Nerves
Mitchell, G. A. G. (1969) · Postgraduate Medical Journal · doi:10.1136/pgmj.45.525.459-a · Cited by 322 · see citing works
Goldman, L., & Albus, J. S. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86510-5 · Cited by 275 · see citing works
Digital Computer Solutions for Excitation and Propagation of the Nerve Impulse
Cooley, J. W., & Dodge, F. A. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86679-1 · Cited by 272 · see citing works
Computation of Impulse Initiation and Saltatory Conduction in a Myelinated Nerve Fiber
Fitzhugh, R. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86837-4 · Cited by 226 · see citing works
Fiber analysis of the statoacoustic nerve of guinea pig, cat, and monkey
Gacek, R. R., & Rasmussen, G. L. (1961) · The Anatomical Record · doi:10.1002/ar.1091390402 · Cited by 222 · see citing works
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216 · see citing works
Peckham, P. H., Marsolais, E. B., & Mortimer, J. T. (1980) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(80)80076-1 · Cited by 167 · see citing works
Self-citationThe response of the myelinated nerve fiber to short duration biphasic stimulating currents
van den Honert, C., & Mortimer, J. T. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02363130 · Cited by 152 · see citing works
Self-citationPeckham, P. H., Mortimer, J. T., & Marsolais, E. B. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363440 · Cited by 145 · see citing works
Self-citationClosed-Loop Control of Force During Electrical Stimulation of Muscle
Crago, P. E., Mortimer, J. T., & Peckham, P. H. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326738 · Cited by 135 · see citing works
Self-citationCrago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133 · see citing works
Self-citationBrummer, S. B., & Turner, M. J. (1975) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(75)80002-x · Cited by 132 · see citing works
Intramuscular electrical stimulation: Tissue damage
Mortimer, J. T., Kaufman, D., & Roessmann, U. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02364479 · Cited by 123 · see citing works
Self-citationA Percutaneous Wire Electrode for Chronic Research Use
Caldwell, C. W., & RESWICK, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324516 · Cited by 79 · see citing works
The excitability of a single fibre in a nerve trunk
Lussier, J. J., & Rushton, W. A. H. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004734 · Cited by 32 · see citing works
PAIN RESPONSE TO DIFFERENT TETANIZING CURRENTS.
VODOVNIK, L., Long, C., & Lippay, A. L. (1965) · PubMed · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442 · see citing works
The neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230 · see citing works
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222 · see citing works
Self-citationThe effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215 · see citing works
Self-citationSafety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198 · see citing works
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185 · see citing works
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Self-citationRamasubbu, R., Lang, S., & Kiss, Z. H. T. (2018) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2018.00302 · Cited by 111 · see citing works
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109 · see citing works
Self-citationMcCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446202 · Cited by 97 · see citing works
A modeling study of nerve fascicle stimulation
Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32100 · Cited by 95 · see citing works
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510526 · Cited by 95 · see citing works
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · see citing works
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41 · see citing works
Liu, X., Demosthenous, A., Vanhoestenberghe, A., Jiang, D., & Donaldson, N. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174360 · Cited by 39 · see citing works
ICFEM 2000. Third IEEE International Conference on Formal Engineering Methods
(2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867869 · Cited by 20 · see citing works
- Authors
- Gorman, P. H., & Mortimer, J. T.
- Affiliations
- Case Western Reserve University (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1983-07
- Volume
- BME-30
- Issue
- 7
- Pages
- 407-414
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2068982338
- Cited by
- 313
- References
- 19
- Citations by year
- 2026: 7 · 2025: 10 · 2024: 8 · 2023: 14 · 2022: 23 · 2021: 15 · 2020: 13 · 2019: 12 · 2018: 10 · 2017: 10 · 2016: 6 · 2015: 11 · 2014: 12 · 2013: 5 · 2012: 8
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- stimulus parameters, pulse duration, biphasic stimulation, cuff electrodes, muscle force measurement, nerve trunks
- MeSH terms
- Animals, Cats, Electric Stimulation, Electric Stimulation Therapy, Muscles, Nerve Fibers, Neural Conduction, Paralysis, Recruitment, Neurophysiological
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review