The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
EEG and MEG: forward solutions for inverse methods
Abstract
A solution of the forward problem is an important component of any method for computing the spatio-temporal activity of the neural sources of magnetoencephalography (MEG) and electroencephalography (EEG) data. The forward problem involves computing the scalp potentials or external magnetic field at a finite set of sensor locations for a putative source configuration. We present a unified treatment of analytical and numerical solutions of the forward problem in a form suitable for use in inverse methods. This formulation is achieved through factorization of the lead field into the product of the moment of the elemental current dipole source with a "kernel matrix" that depends on the head geometry and source and sensor locations, and a "sensor matrix" that models sensor orientation and gradiometer effects in MEG and differential measurements in EEG. Using this formulation and a recently developed approximation formula for EEG, based on the "Berg parameters," we present novel reformulations of the basic EEG and MEG kernels that dispel the myth that EEG is inherently more complicated to calculate than MEG. We also present novel investigations of different boundary element methods (BEM's) and present evidence that improvements over currently published BEM methods can be realized using alternative error-weighting methods. Explicit expressions for the matrix kernels for MEG and EEG for spherical and realistic head geometries are included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
An Analysis of the Finite Element Method
I., E., Strang, G., & Fix, G. J. (1974) · Mathematics of Computation · doi:10.2307/2005716 · Cited by 3,484
An analysis of the finite element method
(1980) · Advances in Water Resources · doi:10.1016/0309-1708(80)90069-x · Cited by 3,466
Brebbia, C. A., Telles, J. C. F., & Wrobel, L. C. (1984) · Springer eBooks · doi:10.1007/978-3-642-48860-3 · Cited by 3,151
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationRealistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
The Solid Angle of a Plane Triangle
Van Oosterom, A., & Strackee, J. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325207 · Cited by 337
On Bioelectric Potentials in an Inhomogeneous Volume Conductor
Geselowitz, D. B. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86571-8 · Cited by 332
Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
Geselowitz, D. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066765 · Cited by 318
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
Magnetic Fields of a Dipole in Special Volume Conductor Shapes
Cuffin, B. N., & Cohen, D. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326145 · Cited by 238
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
Self-citationA fast method for forward computation of multiple-shell spherical head models
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90113-9 · Cited by 230
Source parameter estimation in inhomogeneous volume conductors of arbitrary shape
Oostendorp, T. F., & van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19859 · Cited by 226
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
de Munck, J. C. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256433 · Cited by 193
Zhang, Z. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/3/001 · Cited by 192
MEG-based imaging of focal neuronal current sources
Phillips, J. W., Leahy, R. M., & Mosher, J. C. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585768 · Cited by 190
Self-citationBrain stimulation using electromagnetic sources: theoretical aspects
Heller, L., & van Hulsteyn, D. B. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81587-4 · Cited by 178
Determining Surface Potentials from Current Dipoles, with Application to Electrocardiography
Barr, R. C., Pilkington, T. C., Boineau, J. P., & Spach, M. S. (1966) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1966.4502411 · Cited by 163
Effects of head shape on EEGs and MEGs
Cuffin, B. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 153
Lynn, M. S., & Timlake, W. P. (1968) · SIAM Journal on Numerical Analysis · doi:10.1137/0705027 · Cited by 113
A method for localizing EEG sources in realistic head models
Cuffin, B. N. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362917 · Cited by 109
Eccentric Dipole in a Spherical Medium: Generalized Expression for Surface Potentials
Brody, D. A., Terry, F. H., & Ideker, R. E. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324177 · Cited by 107
Magnetocardiographic functional localization using a current dipole in a realistic torso
Nenonen, J., Purcell, C., Horáček, B. M., Stroink, G., & Katila, T. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83565 · Cited by 97
Evaluation of boundary element methods for the EEG forward problem: effect of linear interpolation
Schlitt, H. A., Heller, L., Aaron, R., Best, E., & Ranken, D. M. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362919 · Cited by 81
Physical Concepts and Mathematical Models
Tripp, J. H. (1983) · Biomagnetism · doi:10.1007/978-1-4757-1785-3_6 · Cited by 79
Ferguson, A. S., & Stroink, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.641342 · Cited by 72
Deflated Decomposition of Solutions of Nearly Singular Systems
Chan, T. F.-C. (1984) · SIAM Journal on Numerical Analysis · doi:10.1137/0721050 · Cited by 61
The numerical solution of singular integral equations of potential theory
Lynn, M. S., & Timlake, W. P. (1968) · Numerische Mathematik · doi:10.1007/bf02165473 · Cited by 53
Improved method for computation of potentials in a realistic head shape model
Fletcher, D. J., Amir, A., Jewett, D. L., & Fein, G. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.469376 · Cited by 49
Moving dipole inverse solutions using realistic torso models
Purcell, C., & Stroink, G. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68213 · Cited by 35
A 24-Channel Planar Gradiometer: System Design and Analysis of Neuromagnetic Data
Hämäläinen, M. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_142 · Cited by 25
Urankar, L. (1990) · Engineering Analysis with Boundary Elements · doi:10.1016/0955-7997(90)90035-8 · Cited by 22
Projective Methods for the Magnetic Direct Problem
Gonzalez, S., de Peralta, R. G., Biscay, R., Jiménez, J. C., Pascual, R. D., Lemagne, J., & Valdes-Sosa, P. A. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_136 · Cited by 12
Neuromagnetic field computation using the multiple multipole method
Haueisen, J., Hafner, C., Nowak, H., & Brauer, H. (1996) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · Cited by 11
Comparison of the Constant and Linear Boundary Element Method for EEG and MEG Forward Modeling
Mosher, J. C., Chang, C.-W., & Leahy, R. M. (2000) · Springer eBooks · doi:10.1007/978-1-4612-1260-7_74 · Cited by 6
Self-citationA modified boundary element method for the estimation of potential fields on the scalp
Srebro, R. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.495284 · Cited by 5
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationNolte, G. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/22/002 · Cited by 1,022
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Metadata
- Authors
- Mosher, J. C., Leahy, R. M., & Lewis, P. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-03
- Volume
- 46
- Issue
- 3
- Pages
- 245-259
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2113431893
- Cited by
- 839
- References
- 42
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.